There is no price at present, you can Request a Quote
Voltage: three phase
Input: 3PH 380-460V 50-60HZ
Output: 3PH 380-460V 5-400HZ
HITACHI VFD Frequency Converter SJ200-075HFR
There is no price at present, you can Request a Quote
People who bought this item also viewed
MTL Encoder MAS-20-256N1
SIEMENS Actuator GLB332.1E
Omron PLC XWT-OD16-1
JSCC Speed Reducer 90GF180H
MITSUBISHI Spindle Amplifier MDS-B-SP-185
INFINEON IGBT Module BSM25GD120DN2E3224
BAOTE Battery BT-FT-150-12
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HONGFA Relay HF18FF-012-4Z2
Balluff Sensor BES02W2
Rexroth Piston Pump A7VO160LRH1/63R-NZB01
Westinghouse Circuit Breaker HFD65K
Festo Sensor SPAB-P10R-N18-NB-L1
Autonics Rotary Encoder E40H6-1024-6-L-5
Recent related posts
-
08/20/2020
How to prevent moisture caused by steam penetration in cold storage projects
Under normal circumstances, excessive air humidity causes rapid growth of mold, moldy food, and corrosion of cold storage building materials. Therefore, the moisture-proof of cold storage projects is also particularly important.
-
03/07/2023
The Differences of Double Acting Cylinder and Single Acting Cylinder
the single acting cylinder acts on one end of the piston, while the double acting cylinder acts as one end of the piston.
-
08/04/2020
The advantages and disadvantages of the fluorine system and the water system are compared!
The advantages and disadvantages of the fluorine system and the water system are compared! Central air-conditioning is mainly divided into two categories: fluorine system and water system, both of which are connected to multiple indoor units by one outdoor unit,
-
07/25/2023
Is Your Heat Pump Making Loud Noise? Here's What You Need to Know
Heat pumps are becoming increasingly popular as an efficient way to heat and cool homes. Not only do they provide consistent temperatures and save money on energy bills, but they also have a smaller carbon footprint than traditional HVAC systems.
-
09/07/2020
Inverter 35 Q
1. What is an inverter? Inverter is an electric energy control device that uses the on-off action of power semiconductor devices to transform industrial frequency power into another frequency.
-
05/27/2022
Level of Safety Light Curtain?
In modern chemical plants, people work together with mechanical equipment. Mechanical equipment is becoming more and more automatic, and workers are more and more likely to be hurt.
-
06/14/2020
Tube heat exchanger
The casing heat exchanger is a carrier that transfers part of the heat of the hot fluid to the water. It uses high-efficiency screw-shaped copper tubes and wraps the treated galvanized steel pipes to realize the process of refrigerant water-filling, allow 器2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/09/2020
The classification and function of filters
air filter The prototype of air filter is a respiratory protection device used by people to protect the breath. According to records, as early as the first century in Rome, people used hemp masks for protection when they purified mercury. In the long time since then, air filters have also made progress,
-
03/21/2022
How to Select Linear Guideways?
Whether we use linear guideways in 3D printers, automatic dispensing machines, automatic screen printing machines, CNC machine tools, CNC machining centers