Belimo Actuator NV230-3
Type: Actuator
Brand: Belimo
Type: Actuator
Brand: Belimo
Type: Actuator
Brand: Belimo
Belimo Actuator AF24-SR
Belimo Actuator SY3U230-MF-T
Belimo Actuator SMS24-MF
Johnson Controls Actuator M9106-AGA-4
Belimo Actuator AF230-S
Johnson Controls Actuator M9216-GGA-2
AirTAC Air Cylinder MA50X210SCM
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
NACHI Piston Pump PVS-1B-16N2Q1-12
AirTAC Air Cylinder MAJ50X200-80S
Rexroth Piston Pump A11VLO260DR/11R-NPD12N00
CRYDOM Relay CWU24125
Banner Sensor SM312CV2GMHSQDP
11/10/2022
Industrial fans, which can efficiently push a large amount of air and generate super-large air volume. This creates a circulating airflow field in the space.
09/20/2020
Mineral oil (MineralLubricant) Mineral oil is a lubricating oil extracted from petroleum. The base oil of mineral oil is the bottom oil left over after the fractional distillation of useful light substances (such as aviation oil, gasoline, etc.) during crude oil refining. Into the product. Essentially, it uses the poorer components of crude oil. Mineral oil is currently the most common type of lubricant on the market.
06/14/2020
The amount of fluoride added to large central air conditioners is generally more, and there are more types of refrigerants. The specific amount can be added according to the label on the nameplate. It is necessary to grasp the amount.
08/11/2020
Compared with ordinary air conditioners, the good explosion-proof performance of explosion-proof chemical air conditioners is an important factor in the selection of enterprises.
09/08/2020
The working principle of the suction dryer (also known as the adsorption dryer) is to reduce the moisture content in the compressed air by using the characteristics of the adsorbent to absorb moisture. Generally speaking, the pressure dew point of the outlet air of the suction dryer reaches -20℃~-70℃ .
06/23/2020
1.If it is because of the weather, you need to change the refrigerator to another location. 2. When used in winter, you can turn on a compensation switch in the refrigerator. 3. It is necessary to check whether the compressor is damaged. 4. If the modulation gear is incorrect, you can adjust the gear higher. 5. If the refrigerant is not enough, the problem of non-refrigeration can be solved after the fluorine content is added.
12/05/2020
Air compressor dew point meter-suitable for compressed air and compressor post-processing drying equipment dew point meter, Michell products include a variety of online dew point meter and portable dew point meter, as well as dew point meter analysis system, fast response speed and good reliability.
09/14/2020
Cement plants have many production and grinding processes, and the ambient air contains high dust concentrations. The original design of dust removal filter device used in air compressor is mostly paper filter element dust removal.
07/20/2020
A. During the initial operation of the cold storage unit, carefully observe the oil return of the compressor and keep it clean. If you find that the oil level is not clean enough or if the oil level drops, you should add oil or replace it with new oil in time. This can avoid poor lubrication
09/22/2020
1 Introduction The catalytic cracking rich gas compressor is a kind of compressor, which is very representative. For this reason, the catalytic cracking rich gas compressor is taken as an example to discuss the calculation method of the surge line of the rich gas compressor control system.