There is no price at present, you can Request a Quote
MEDAN Air Cylinder PLF50-900
There is no price at present, you can Request a Quote
People who bought this item also viewed
MINDMAN Air Cylinder MCGB-23-25-20
Festo Air Cylinder ADN-32-15-I-P-A
Festo Air Cylinder DSNU-20-100-PPV-A
TPC Air Cylinder NFP2-25D-T
LS Mecapion Encoder S48-8-2048ZO
Honeywell Actuator V4055A1031
SMC Proportional Valve ITV2030-213BN4
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder SED80X100S
Daikin Air Conditioner FQDP56EPVC
HENGYI Vane Pump SVQ45-200-F-RAL-01
DAYTON Speed Reducer 2H563
Recent related posts
-
06/25/2020
[Information] The functions and characteristics of commonly used compressed air flow meters
[Information] The functions and characteristics of commonly used compressed air flow meters 1. The role of compressed air flowmeter Compressed air is an important secondary energy source for enterprises and institutions, most of which is converted from electrical or thermal energy by compressors.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/17/2020
Causes and solutions for high-pressure alarms of refrigerators
Generally, the refrigerator is equipped with a full set of protection devices. When the refrigerator has a high-pressure alarm, it will automatically start the protection device, and the corresponding fault indicator will light up
-
07/01/2020
How to check the compressor body for cracks
How to check the compressor body for cracks In winter, it is relatively common for compressors to crack. I believe many people have ideas to prevent this kind of problem. In fact, it is not impossible, as long as we conduct a detailed inspection of the compressor body during normal maintenance, this problem can be avoided.
-
11/02/2023
What is a Rotary Screw Air Compressor? Everything You Need to Know
Rotary screw air compressor (screw air compressor, screw type air compressor, rotary screw compressor), is a positive displacement air compressor
-
03/13/2021
Working mode of servo driver
The working modes of servo driver are: open loop mode, voltage mode, current mode (torque mode), IR compensation mode, Hall speed mode, encoder speed mode, tachometer mode, and analog position loop mode (ANP mode). (not all of the above modes exist in all models of drives)
-
08/14/2020
How to deal with moldy cold storage accessories
1. Analyze the reasons<br></br> Inspect the entire refrigeration system to confirm the cause of frost damage and find out the leaks
-
07/05/2020
Global HVAC Centrifugal Compressors Market 2020-2025 Report and Imapct of Coronavirus Pandemic
The “Portable Air Compressor” Market report considers the central point responsible for driving the development of the Snowblowers Industry, notwithstanding the key preventions and difficulties.
-
01/26/2023
How to Maintain a Pressure Transmitter
In order to prolong the service life of the pressure transmitter and reduce the error, regular inspection and maintenance are recommended, such as weekly inspection.
-
08/19/2020
Why do industrial chillers need to replace high-quality antifreeze regularly
When the industrial chiller is running, there are high requirements for the use of antifreeze. Ordinary equipment cannot use high concentration antifreeze. If the concentration of antifreeze is high, it takes a long time to warm up before operating the equipment.