There is no price at present, you can Request a Quote
Operation: double acting single pole
Fluid: air
Operation ambient temperature range: 5 - 60 degree celsuis
Bore size: 16mm
Stroke: 20mm
TPC Air Cylinder ACPL16-20
There is no price at present, you can Request a Quote
People who bought this item also viewed
TPC Air Cylinder AMRBH25-1400
TPC Air Cylinder AGL63-50
TPC Air Cylinder NLCD25-50RF
TPC Air Cylinder NLCD12-30R-W8H
Festo Air Cylinder DSNU-16-25-P-A-S2
TPC Air Cylinder NLCD12-100S
Festo Air Cylinder DGP-25-700-PPV-A-B
AirTAC Air Cylinder SC200X400
AirTac Solenoid Valve 3V220-15
SIEMENS Actuator GLB331.9E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
USING Solenoid Valve FMS-GO12-03B
Donaldson Filter P550276
AirTAC Air Cylinder SCJ32X250-25
Banner Sensor SLM80N6Q
Ding Zing Oil Seal UN130*150*16
Recent related posts
-
09/07/2020
An article to fully understand the principle, failure and maintenance of nitrogen compressors
Nitrogen compressors are mainly used in various industrial needs. Pipes are used to connect the original air inlet of the nitrogen compressors and the balance gas tank. When the sealing performance of the sealing box is not very good, the pipeline provides a certain pressure ,
-
12/05/2021
Principles and Differences of 2-wire, 3-wire, and 4-wire Transmitters
2-wire, 3-wire, and 4-wire transmitters refer to the transmitters whose outputs are analog DC current signals.
-
09/04/2020
The difference between air compressor inverter and soft starter
Soft starter concept Soft start (also known as soft starter, motor soft starter, soft starter) Soft start is a novel motor control device that integrates motor soft start, soft stop, light load energy saving and multiple protection functions.
-
06/29/2022
Installation of Axial Piston Pump
The installation quality of axial piston pump is very important. If it is not installed properly, it will have a direct impact on the service life and even be damaged soon.
-
08/20/2020
Treatment method of ammonia leakage accident in ammonia refrigeration compressor
During the operation of the cold storage, the maintenance and maintenance of the ammonia refrigeration system are not in place, which will cause some failures in the ammonia refrigeration system.
-
06/14/2020
At Schneider Electric, we believe that obtaining energy and using digital technology are people ’s basic power
At Schneider Electric, we believe that obtaining energy and using digital technology are people ’s basic power. We empower everyone to maximize the use of energy and resources, and ensure that everyone can enjoy Life at any time and any place. Is On.
-
09/04/2020
The composition and function of the air compressor oil return check valve
The oil return check valve is composed of valve body, steel ball, steel ball seat, spring and other elements. The oil and gas mixture compressed by the main engine of the air compressor is initially separated in the oil and gas tank by centrifugal force.
-
09/09/2020
Classification of air filters
Air filter has three methods: inertia, filtration and oil bath. ①Inertial type: Since the density of impurities is higher than that of air, when the impurities rotate or make sharp turns with the air, the centrifugal inertial force can separate the impurities from the airflow.
-
06/21/2020
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high Compressor suction pressure is too high, discharge pressure is too high 1. Too much refrigerant. Too much refrigerant will cause the suction pressure and discharge pressure to be too high at the same time. This is because when too much refrigerant fills the reservoir, it will occupy a part of the condenser volume, reducing the heat dissipation area and causing the condenser Poor condensation. Discharge excess refrigerant from the low-pressure side.
-
06/14/2020
Cause Analysis of Refrigeration Compressor
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start 1) First check the main circuit. Whether the power supply has power, whether the voltage is normal,