Fluid: Air(to be filtered by 40u m filter element)
Operating pressure:
Double acting: 0.2 to 0.7 Mpa(28 to 100psi)(2.0 to 7.0 bar) or 0.1 to 0.7 Mpa(15 to 100psi) (1.0 to 7.0 bar)
Single acting: 0.3 to 0.7 Mpa(36 to 100psi)(3.0 to 7.0 bar)or 0.2 to 0.7 Mpa(28 to 100psi)(2.0 to 7.0 bar)
Proof pressure: 1.1MPa(160psi)
Temperature(degrees Celsius): -20 to 70
Speed range(mm per second): 30 to 500 or 50 to 800
Cushion type: No cushion or Bumper
Bore size:10mm
Stroke:100mm
Magnet:with magnet
AirTAC Air Cylinder Pneumatic PB10X100SPen size Cylinder Pneumatic(Double acting)
People who bought this item also viewed
Festo Air Cylinder AEVULQZ-16-10-P-A
Festo Air Cylinder CRDNG-125-100-PPV-A
AirTAC Air Cylinder HRQ2
AirTAC Air Cylinder MA32X25S-CA
AirTAC Air Cylinder MAC32X80SCA
Festo Air Cylinder DSNU-32-50-PPV-A
Festo Air Cylinder DSEU-25-25-P-A
Autonics Rotary Encoder E40H8-2-2-V-24
Honeywell Actuator ML7425A6016
SMC Proportional Valve ITV2030-313CL5
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
IFM Sensor MK5317
Recent related posts
-
06/14/2020
Scroll compressor 2020 or will enter the dark moment
Scroll compressor 2020 or will enter the dark moment Affected by factors such as product competition and the weakening of downstream demand, in the context of the overall downturn in the HVAC industry,
-
07/28/2021
Daikin Vs. Toshiba Air Conditioners
Daikin in Japan has always maintained the first market share, is the world's only multinational enterprise integrating the air conditioner
-
07/01/2020
How to check the compressor body for cracks
How to check the compressor body for cracks In winter, it is relatively common for compressors to crack. I believe many people have ideas to prevent this kind of problem. In fact, it is not impossible, as long as we conduct a detailed inspection of the compressor body during normal maintenance, this problem can be avoided.
-
04/22/2022
How to Debug The Input Level Transmitter?
Generally, the input level transmitter will be accurately corrected according to the range marked on the nameplate when leaving the factory.
-
09/05/2020
Development of all low-voltage small air separation equipment
In the 1990s, with the deepening of reforms and technological progress, large-scale air separation and liquefaction equipment provided the ability and means to transport liquid products. Tank trucks for liquid oxygen, liquid nitrogen and liquid argon were sold all over the country.
-
09/18/2020
Performance comparison of piston compressor and screw compressor
The noise of the piston engine is loud and the maintenance is inconvenient. Most piston machines often have problems during use, which brings great inconvenience to users. At the same time, it can reduce the production cost of the factory, increase economic benefits, facilitate equipment management, beautify the company's environment, improve company image,
-
06/14/2020
Analysis of the current status of refrigeration compressor technology development
Analysis of the current status of refrigeration compressor technology development
-
09/04/2020
Energy-saving space of screw air compressor itself
When we talk about the energy saving of screw air compressors, we often start from the outside of the air compressor, such as frequency conversion transformation, waste heat recovery, etc.
-
07/31/2020
The weather is getting colder and you need to pay attention to these hidden dangers when using air conditioners!
Soon after the summer ends, it feels like a direct transition to winter. The weather began to cool down, and many families began to use air-conditioning and other heating equipment one after another.
-
01/29/2024
The Role of UPS and How to Solve Its Heat Dissipation Problem (UPS Cooling Fan)
(Uninterruptible Power Supply) is a power supply that contains an energy storage device. It is mainly used to provide uninterrupted power for some equipment that requires high power supply stability, such as a single computer, computer network system