Coil Voltage:DC24V
AirTac Solenoid Valve 3V310-DC24V
People who bought this item also viewed
AirTac Solenoid Valve 4V21008B
AirTac Solenoid Valve 3V2-06-NC
AirTac Solenoid Valve 2L050-15-DC12V
CHELIC Solenoid Valve SV-5101-W
CKD Solenoid Valve 4GA219R-C6-E2-3
Bristol Compressor H2NG124DPEF
Dwyer Transmitter 3200G-1-FM-1-1-LCD
TRIAD Transformer TCT3-03E07AE
Parker Sporlan Expansion Valve FHVE-8
Amico Check Valve 9418 DN150
SMC Overflow Valve VKF332V-5G-01
YUKEN Piston Pump A70-L-R-01-K-S-60
HOERBIGER Gear Pump HQ12-022RA04-11S101
EMERSON Sight Glass AMI-2S11
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CASTEL Safety Valve 3060/33C280
Furnan Vane Pump 50T-26-FR+PA-1
EAST Power Supply EA660
HYTEK Gear Pump CP1-50-P-10R
Advantech PLC UNO-1252G
Recent related posts
-
01/26/2022
A Quick Look at the Submersible Pressure Transmitter
Submersible pressure transmitters use imported chip assembly, reflecting the superior technology. Their structure is compact and firm and is light for installation.
-
09/11/2022
Choose the Right Circuit Breaker?
Circuit breakers are widely used in electromechanical equipment and circuits. However, as different protected objects have different abilities of overload current bearing
-
07/08/2020
How to solve the problem of poor oil return of screw chiller
1. What is the cause of the poor oil return of the screw chiller? Generally speaking, the reason for the poor oil return of the screw chiller is mainly due to the phenomenon of the gas mixture of lubricating oil and refrigerant during the operation. Specifically, in the operation of the refrigeration system, encountering the miscibility of the refrigerant and the refrigerator lubricating oil will cause the lubricant in the refrigeration compressor to run and the refrigerant will be discharged into the condenser in the form of gas mist and droplets.
-
08/14/2020
Factors affecting the boiling heat transfer of refrigerant liquid
In the evaporator, the heat of the cooled medium is transferred to the refrigerant through the heat transfer wall, so that the liquid refrigerant absorbs heat and vaporizes.
-
03/25/2022
How Does a Circuit Breaker Work?
Circuit breakers are an essential part of any electrical system. Circuit breakers protect homes from various electrical hazards (such as overloading) and cut off power if the current becomes unsafe.
-
08/13/2020
Correct operation method and precautions of distribution box during cold storage installation
In the process of cold storage installation, the use of cold storage power distribution boxes is a very important content, but most people are not very familiar with the normal operation of cold storage power distribution boxes.
-
08/04/2020
The advantages and disadvantages of the fluorine system and the water system are compared!
The advantages and disadvantages of the fluorine system and the water system are compared! Central air-conditioning is mainly divided into two categories: fluorine system and water system, both of which are connected to multiple indoor units by one outdoor unit,
-
06/13/2020
Commercial Refrigeration Compressor Market to Surge at 221.7 Million units by 2026; Introduction of Advanced Technologies to promote Growth, Says Fortune Business Insights™
Key Companies Covered in Commercial Refrigeration Compressor Market Research Report Are Carrier Corporation, Daikin Industries Ltd., Johnson Controls Pvt. Ltd., Mitsubishi Electric, Bitzer, Emerson Climate Technologies, Ingersoll Rand Inc., Rechi Precisio 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦
-
08/12/2020
Symptoms and causes of car air conditioner compressor not working and blower not working
Fault description When the air-conditioning refrigeration switch is turned on, the compressor does not turn, but after turning on the blower switch, the blower can run<
-
04/20/2022
Six Level Measuring Instruments and Relative Merits?
Float level meter is an instrument of measuring liquid level based on buoyancy principle. Usually, the combination of floating ball and scale enables the observer to intuitively read the height of liquid level.