120°-135°-180° rotation both in double acting and spring return
180° spring return Fail-Mid
3 Position actuators, 90° and 180° rotation, both double acting and spring return versions
Fast acting actuators
Hydraulic damper actuators
Lock-Out capability in fully open or fully close position
100% travel stop adjustment
AIR TORQUE Ball Valve PT400DA
People who bought this item also viewed
ROTEN Mechanical Seal 8E5K-22-X
MINDMAN Air Cylinder MCGJ-12-32-50
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Fuji Contactor SC-E3PCS
SMC Solenoid Valve VFS2120-4G-02
Recent related posts
-
06/21/2020
Composition principle of refrigeration system of refrigerator
Composition principle of refrigeration system of refrigerator Refrigerators have a larger cooling capacity than household refrigerators, and there are more refrigerants filled in the system. Therefore, a liquid storage tank is installed on the pipeline between the condenser and the filter, and a shut-off valve is installed on the tank to shut down the system for a long time. When closing the shut-off valve, the refrigerant liquid is stored in the tank.<img src="{{media url="Composition_principle_of_refrigeration_system_of_refrigerator.jpg"}}" alt="" />
-
07/23/2020
The influence of capillary tube length on refrigeration system parameters and troubleshooting
The capillary tube generally refers to a slender copper tube with an inner diameter of 0.4~2.0mm. As the throttling mechanism of the refrigeration system, the capillary tube is the simplest one. Because of its low price and flexible selection, it is widely used in small refrigeration devices.
-
06/24/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
08/21/2020
Common problems and solutions for ice making machines
1. Common problems and solutions of ice maker 1. The compressor is working but not cooling. Reason: The refrigerant leaks or the two-way solenoid valve is damaged and it is not closed tightly.
-
07/03/2020
GLOBAL REFRIGERANT COMPRESSOR MARKET COMPANY PROFILE, REGIONAL ANALYSIS, INDUSTRY GROWTH 2020-2025
According to a new report published by Eon Market Research, titled, ”Global Refrigerant Compressor Market by Product Type and End-Users/Application Global Market Share, Forecast Data, In-Depth Analysis, and Detailed Overview, and Forecast, 2020 – 2025″ – By Regions (USA, Europe, Japan, China, India, South East Asia).
-
09/07/2020
The difference between permanent magnet variable frequency air compressor and ordinary air compressor
With the development of science and technology, air compressors, as an important power equipment, are widely used in many industrial fields such as machinery, metallurgy, building materials, electronics and electricity, chemicals, food, and textiles.
-
01/31/2024
How Does a Wood Stove Fan Work?
Wood stoves have been a reliable source of warmth for centuries, providing a cozy atmosphere during chilly days.
-
09/08/2020
What environment will affect the operation of the air compressor
The surrounding environment of the air compressor will also have a significant impact on the operation of the air compressor. The following phenomena are mainly caused by the analysis of the cause of the failure caused by the bad surrounding environment, so the user should try to meet the standard requirements when installing the air compressor to deal with the surrounding environment .
-
06/20/2020
Common fault phenomena, causes and elimination methods of piston compressors
Common fault phenomena, causes and elimination methods of piston compressors Common faults of piston compressor (1) Phenomenon: the compressor cannot start Reasons: 1. Electrical circuit failure; 2. High and medium voltage relay and oil pressure relay are disconnected.<img src="{{media url="Common_fault_phenomena_causes_and_elimination_methods_of_piston_compressors.jpg"}}" alt="" />
-
07/15/2020
What you need to know about the electrical connection of Copeland refrigeration compressors
Please pay attention to the direction of the terminals in the junction box (single-phase: R, S, C; three-phase: T1, T2, T3). In order to ensure the normal start-up and operation of the Copeland refrigeration compressor, the power supply voltage cannot be lower than 10% of the Copeland compressor rated voltage.