Stock number:S55232-V107
Kvs( nominal flow rate of cold water (5…30 °C) through the fully open ball valve at a differential pressure of 100 kPa (1 bar)):160[m3/h]
Sv (rangeability):200kvs / kvr
∆pmax(Maximum permissible differential pressure across valve’s control path, valid for the entire actuating range of the motorized valve.):400
∆ps (Maximum permissible differential pressure at which the motorized valve will close securely against the pressure (close off pressure).):400
L:115[mm]
L1:207[mm]
L2:44[mm]
L3:18[mm]
D:155[mm]
n:8
D2:19[mm]
D4:100[mm]
D5:180[mm]
H >570
H1:171[mm]
H2:369[mm]
H3:264[mm]
Weigh:9.1[kg]
Working pressure and medium temperature as per IS0 7005 Current local legislation must be observed.
SIEMENS Ball Valve VAF41.100-160
People who bought this item also viewed
ROTEN Mechanical Seal 8E5K-22-X
SCHNEEBERGER Linear Guideway MRW25C-G1V1
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Circuit Breaker 3RV2411-1EA15
AirTAC Air Cylinder ACQ125X175
CKD Air Cylinder CMK2-CC-40-300
Recent related posts
-
03/01/2024
A Guide to Fresh Air Ventilation System: Working Principle, Functions & Types
Fresh air ventilation system, also known as "house breathing system", is a type of indoor exhausting and ventilation system. It can discharge the dirty indoor air to the outside while also pulling fresh outdoor air into the room.
-
06/02/2023
What Causes AC Compressor Failure and How to Prevent It? (11 Reasons&4 Ways)
The AC compressor is an essential component of an air conditioning system, responsible for compressing and circulating refrigerant that cools down the air.
-
10/29/2022
What is a Servo Drive
Servo drive, also known as "servo controller" and "servo amplifier", is a controller used to control servo motors, and its function is similar to that of frequency converters used for ordinary AC motor.
-
09/12/2022
Differences between Circuit Breaker and Isolator Switch?
A circuit breaker refers to a switching device that can close, carry and break current under normal circuit conditions and can do the same under abnormal circuit conditions within a specified time.
-
09/21/2020
Refrigeration system failure symptoms
Symptoms of refrigeration system failure 1. Detection of pressure and temperature of refrigeration system (1) The pressure concept of the refrigeration system The refrigeration system can be divided into high and low pressure during operation. The high pressure section is from the discharge port of the compressor to before the throttle valve. This section is called the evaporation pressure.
-
07/31/2020
The 8 accessory usages that must be mastered when using computer room air conditioners!
The electrical control and air circulation of the computer room air conditioner are independent units. During maintenance and overhaul, the air conditioner does not need to be turned off, and the stable air flow and temperature gradient in the air conditioner room can also be ensured
-
08/04/2020
Why is the compressor short of oil, and why does the evaporator have an oil film
The compressor is a complex machine that runs at high speed. Ensuring adequate lubrication of the compressor crankshaft, bearings, connecting rods, pistons and other moving parts is the basic requirement for maintaining the normal operation of the machine
-
09/15/2021
6 Reasons for Refrigeration Compressor Not to Start
When speaking of air conditioners, everyone is familiar with them. Especially in the hot summer, we would not know how to live without it.
-
09/27/2022
What is a Hydraulic Vane Pump?
With the development of hydraulic technology, vane pump, as an indispensable power element, has been more and more deeply penetrated into various fields such as hydraulic systems
-
06/21/2020
Common system failures of refrigeration equipment
Common system failures of refrigeration equipment 1. Liquid return: For refrigeration systems using expansion valves, liquid return is closely related to the selection and use of expansion valves. Expansion valve selection is too large, the superheat setting is too small, the installation method of the temperature sensor is incorrect, the insulation bandage is damaged, and the expansion valve failure may cause liquid return.<img src="{{media url="Common_system_failures_of_refrigeration_equipment2.png"}}" alt="" />