CINO Bar Code Scanner FA470
Type: Bar Code Scanner
Brand: CINO
Type: Bar Code Scanner
Brand: CINO
Type: Bar Code Scanner
Brand: CINO
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
Festo Air Cylinder CRDNG-100-80-PPV-A
Fuji Circuit Breaker BW250EAG-3P175
Siemens Circuit Breaker 5SY6310-8CC
CHELIC Air Cylinder JDD40*75
REGO Safety Valve PRV9432F050C
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SMC Solenoid Valve AV2000-02-5DB-R
Fuji Belt A-133
AirTAC Air Cylinder JSIJ80X900-50
Beckhoff Module KS1164
HENGYI Vane Pump PVF-20-70-10
06/24/2020
Different cooling methods of refrigerators have different advantages, mainly depending on which cooling method is selected. The direct cooling refrigeration type is cheap, relatively energy-saving, and has good fresh-keeping and moisturizing properties, but the temperature is uneven, and it needs to be defrosted frequently.
07/01/2020
The development trend of various air compressors At present, various types of air compressors are used very much. Does this mean that the current development status of air compressors is very good? What is the future development trend of it? As a refrigeration compressor expert, we okmarts.com is very good It is necessary to understand the future development trend of various air compressors. This has a great influence and help on the operation of our compressor.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
07/19/2020
Screw refrigeration compressor is a rotary positive displacement compressor. It uses the change of the cogging volume and position of the screw to complete the process of vapor suction, compression and exhaust. Oil-free screw compressors came out in the 1930s, mainly used to compress air. Later, the oil-injected screw compressor appeared in the cylinder,
07/20/2022
During the operation of the diaphragm pump, there should be no abnormal sound, and all parts should be free of running, emitting, dripping, leakage and other phenomena.
07/23/2020
The refrigeration compressor is the core and heart of the refrigeration system. The capacity and characteristics of the compressor lead to the capacity and characteristics of the refrigeration system. In a sense, the design and matching of the refrigeration system is to reflect the capacity of the compressor.
05/06/2022
When the power is on, the electromagnetic coil generates electromagnetic force to lift the closing part from the valve seat and open the valve
06/27/2020
Inverter compressor refers to a compressor whose relative speed is constant, and whose speed is continuously adjusted within a certain range through a control method or means, which can continuously change the output energy.
06/14/2020
There is solar energy in the water vapor, which can be used for heating and cooling What is water vapor energy? This unfamiliar term is actually not difficult to understand
02/18/2020
The price of refrigerator repair is not familiar to everyone. In summer, it is the most frequently used period of refrigerators, and it is also the period when refrigerators are most prone to failure. The most prone to failures in refrigerators are freezing and non-refrigeration inside the refrigerator. The editor looks at the repair price of the refrigerator without refrigeration and the reasons for the refrigerator without refrigeration, for your reference.<img src="{{media url="magefan_blog/Refrigerator_does_not_cool_repair_price.jpg"}}" alt="" />