Displacements 15.2 - 54 cm3/rev
Maximum continuous pressure 300 bar (depending on displacement)
Fluid temperature range -20 / +90 °C (Extreme condition temperature range: 30 +110 °C)*
Recommended fluids hydraulic mineral oil-based
Standard seals material HNBR standard
BUCHER Gear Pump QX31-032R
People who bought this item also viewed
KITZ Check Valve PN16RDZ
ASHUN Overflow Valve MRV-04B-B-10
Daikin Piston Pump V38A2L-95
ESHINE Vane Pump VPFE-F20-C-10
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Mitsubishi Servo Motor HC-MF43B-S15
SENSORC Light Curtain SEG20-4024P-LO-3-Y
Hisense Air Conditioner KFR-26GW-S700X-X1
KAKU Fan KA8038HA2BAL
Omron PLC CJ1W-NC433
SuperRed Fan CHA9212BB
PIZZATO Switch PC 4-1
OMAL Ball Valve SG100H009
Recent related posts
-
06/20/2020
Structure diagram of single vane compressor_Main features of single vane compressor
The basic structure and working principle of single slide compressor.<img src="{{media url="Structure_diagram_of_single_vane_compressor_Main_features_of_single_vane_compressor.jpg"}}" alt="" /> Single sliding vane compressor is also called scraper compressor or rolling rotor compressor. Its structure is shown in Figure 3-7. A cylindrical eccentric rotor (also called a piston) is installed in the cylinder, and the center of rotation of the rotor coincides with the center of the cylinder. In the middle of the upper part of the cylinder, a scraper that can slide up and down is installed. Due to the force of the spring,<img src="{{media url="Structure_diagram_of_single_vane_compressor_Main_features_of_single_vane_compressor2.jpg"}}" alt="" />
-
07/28/2020
Analysis of common failure causes of hermetic refrigeration compressors
. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.
-
06/29/2020
The role of freezing oil in screw refrigeration compressor
The role of freezing oil in screw refrigeration compressor The role of lubricating oil: 1) A dynamic seal is formed between the screw and the compression chamber and the male and female screws to reduce refrigerant leakage from the high-pressure side to the low-pressure side during the compression process.
-
08/14/2020
How much do you know about water-cooled chillers A few steps let you know
What is the cooling method of the chiller? A water-cooled chiller is one of them. It has many names. Some people say it is a chiller or a chiller. No matter which type, it is the same machine.
-
08/02/2022
What is A Overflow Valve
Overflow valve also called relief valve is a kind of hydraulic pressure control valve, which mainly plays the role of constant pressure overflow, pressure stabilization, system unloading and safety protection in hydraulic equipment.
-
06/14/2020
Refrigeration compressor industry analysis report data
Refrigeration compressor industry analysis report data mainly use national statistical data, General Administration of Customs, questionnaire survey data, data collected by the Ministry of Commerce and other databases. Among them, the macroeconomic data i ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ 뤂ᐱ變뚜珵 ᴴᏩ呄ᠾ
-
03/24/2023
Working Principles of Common Vacuum Pumps
The vacuum pump is a device that vacuumizes the pumped container under the action of electromagnetic force to maintain the vacuum. Vacuum pumps are usually widely used in low temperature equipment, papermaking machinery, vacuum equipment, and petroleum, mining, foundation treatment and other fields.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
02/06/2022
Why Refrigeration Compressor not Work but Operate Normally
In some cases, you would find that the compressor motor starts and runs normally, but it cannot compress the refrigerant.
-
08/06/2020
How to distinguish the authenticity of the compressor of the antifreeze chiller
The familiar "pump" is a mechanical device that can increase potential energy. For example, a water pump mainly pumps water from a low position to a high position.