Features
All models fully comply with IEC regulations
Units can be mounted on a standard 35mm IEC rail
Residual current circuit breakers use an original Mitsubishi Electric IC
securing reliable earth-leakage protection
High current-limiting performance
Compliance with IP2X protection rating
All models are compatible with reverse connection
DC circuit-compatible model (BH-D10) added to product line-up
Mitsubishi Circuit Breaker BV-D 4P 63A
People who bought this item also viewed
Mitsubishi Circuit Breaker NF400-CP
Mitsubishi Circuit Breaker NF225-SP 225A
Siemens Circuit Breaker 3RV2011-1GA20
Fuji Circuit Breaker CP30FM-3P001
Eaton Moeller Circuit Breaker LZMB1-A20
Fuji Circuit Breaker BW250EAG-3P150
Schneider Transformer ABT7PDU025G
Siemens Contactor 3RT2017-1BE42
Ferraz Shawmut Fuse PC273UD11C14CTF
HONGFA Relay HFKP-024-1H5T(136)
Yageo Resistor RC1206JR-072KL
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PIZZATO Switch FD 1899-F1M2
NEC IC Integrated Circuit B553AC
LG LS PLC XGL-EH5T
Recent related posts
-
06/20/2020
Operation process of automobile air-conditioning refrigeration system and the role of pressure switch
Operation process of automobile air-conditioning refrigeration system and the role of pressure switch From top to bottom, automobile air conditioners are mainly composed of blowers, evaporators, pressure switches, dryers, expansion valves, condensers, and the most source compressors. The operation process of this air-conditioning system is: heat dissipation,
-
06/13/2020
The application of photovoltaic central air-conditioning technology will continue to extend
The application of photovoltaic central air-conditioning technology will continue to extend The "Renewable Energy Power Quota Assessment Measures (Trial)" has been discussed and approved in principle by the National Development and Reform Commission's di ﰸ2 䀀
-
09/08/2022
Brushless Vs Brushed Motor
The following article introduces some differences between brushed motors and brushless motors in terms of working principle and performance, hoping to deepen your understanding of them.
-
08/05/2020
How to solve the problem of too high compression ratio of chiller
In the process of using industrial chillers, various problems will inevitably occur. Due to the structure of the industrial chiller, once the compression ratio of the compressor is too high, it will affect the working efficiency of the industrial chiller.
-
06/13/2020
Identify the failure of a fully enclosed refrigeration compressor in three minutes
Identify the failure of a fully enclosed refrigeration compressor in three minutes 1. How to identify the three binding posts on the casing of the hermetic compressor?
-
07/05/2020
Hitachi 2p cold storage compressor
How does the electronic expansion valve reduce the energy loss of the compressor during start and stop? When the compressor is stopped, the electronic expansion valve can completely close the valve to prevent the refrigerant from flowing from the condenser to the evaporator
-
09/14/2020
Troubleshooting of high pressure air compressor
1-0.27/150 Type High Pressure Air Compressor Troubleshooting Method Fault Features Sound in the crankcase Possible cause a. The screw and nut of the connecting rod are loose. Whether the big-end bearing of the connecting rod is loose.
-
09/11/2020
Several Improvements on the Easy Failure Points of Air Compressor
The original compressor has poor cooling effect and low efficiency. The improvement method is to introduce the water that enters the primary and secondary cylinders and the intercooler directly from the main pipe to the water collecting funnel after cooling.
-
06/13/2020
The difference between air conditioning dehumidification and refrigeration
The difference between air conditioning dehumidification and refrigeration Let me talk about the conclusion first: the current home air conditioner, dehumidification is a cooling operation. There are three types of temperature that characterize the state 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱
-
04/25/2023
What are the 4 Main Components in a Central AC System
There are four main components in the central air conditioning system, namely: compressor, condenser, throttling device, and evaporator. Evaporators and condensers are collectively referred to as heat exchangers