Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.16 |
Number of Poles | 2 pole |
Setting range for thermal overload releases | 0.11...0.16 A |
Suitable for induction motors with P | 0.04 kW |
Instantaneous overcurrent releases | 2.1 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.233 kg |
product brand nameSIRIUS
product designation circuit breaker
design of the product for motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
surge voltage resistance rated value 6 000 V
protection class IP on the front IP20
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica l100 000
continuous current rated value 0.16 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation-20 - +60 degrees centigrade
uring storage-50 - +80 degrees centigrade
during transport-50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.11 - 0.16 A
operating voltage rated value 690 V at AC-3 rated value maximum 690 V
operating current at AC-3 at 400 V rated value 0.16 A
operating power at AC-3 at 400 V rated value 0.04 kW
operating frequency at AC-3 maximum 15 1/h
Auxiliary circuit
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No phase failure detection Yes
trip classCLASS 10
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
Short-circuit protection
design of the overcurrent release and short-circuit release thermomagnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
height 90 mm width 45 mm depth 81 mm
required spacing with side-by-side mounting
backwards 0 mm at the side 0 mm
type of electrical connection for main current circuit spring-loaded terminals
for auxiliary and control current circuit spring-loaded terminals
arrangement of electrical connectors for main current circuit front side
type of connectable conductor cross-sections
for main contacts solid 2x (0.25 - 2.5 mm?)
finely stranded with core end processing 2x (0.25 - 1.5 mm?)
finely stranded without core endprocessing 2x (0.25 - 2.5 mm?)
at AWG conductors for main contacts 2x (24 - 14)
Siemens Circuit Breaker 3RV1011-0AA20
People who bought this item also viewed
Fuji Circuit Breaker EW32AFC-2P015
Siemens Circuit Breaker 3RV1011-0HA10
Siemens Circuit Breaker 3RV1031-4DA10
Siemens Circuit Breaker 5SY4113-7
Siemens Circuit Breaker 3RV1011-1CA15
Siemens Circuit Breaker 3RV2021-4BA20
TRIAD Transformer CSE186L
Fuji Contactor SC-E04P-G
PolySwitch Fuse AGRF800-2
TAIAN Relay RHU-5M 1.1-1.6A
UniOhm Resistor 1210W3J0514T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HENGSTLER Encoder RI58-D/150EE.47KB
SMC Solenoid Valve VFR2210-4GB-02
Recent related posts
-
07/27/2021
7 Ways to Save Energy on Your Air Compressor
As one of the power sources of manufacturing and production enterprises, compressed air requires continuous operation of equipment to ensure the stability of air supply pressure
-
08/11/2020
The load calculation formula of computer room air conditioner
The load calculation formula of computer room air conditioner<br></br> How to obtain heat and cooling load in the computer room and how to calculate the cooling capacity required in the constant temperature and humidity room.
-
06/13/2020
Solar driven adsorption refrigeration
Solar driven adsorption refrigeration Shanghai Jiaotong University Wang Ruzhu and other nearly 20 years of painstaking research "adsorption refrigeration adsorption mechanism, cycle construction and thermal design theory" won the second prize of the 2014 ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ
-
09/04/2021
Where is the Throttle Position Sensor Located?
The throttle Position Sensor (TPS), located on the butterfly spindle, is operated by the throttle, and its installation varies according to the structure.
-
06/21/2020
Reasons for poor cooling of air conditioners
The temperature in summer is high, and many of the owners' friends need air conditioning to spend the hot summer in the room. However, some owners often have such problems when using air conditioning in summer, such as poor air conditioning cooling. So, what are the reasons for poor air conditioning and cooling? How to solve the poor air conditioning and cooling? One of the reasons for poor air-conditioning and cooling: Freon is not enough (commonly known as fluoride deficiency) <img src="{{media url="magefan_blog/Reasons_for_poor_cooling_of_air_conditioners.jpg"}}" alt="" />
-
09/09/2020
The composition of air compressor oil
Air compressor coolant, referred to as air compressor oil in the industry, is indispensable for air compressor equipment. Air compressor oil plays a role in lubricating, protecting, reducing friction, sealing, rust prevention, and corrosion during the operation of the air compressor. There are two basic components of compressor oil.
-
08/16/2020
The difference between condenser and cooler
There will be compressors, condensers, evaporators, expansion valves and refrigerants in the chiller refrigeration system. Only with the addition of these original parts will a good refrigeration system be formed.
-
02/27/2021
Some common faults and solutions of servo motors
The temperature of the motor is too high or the motor is faulty with smoke the reason: 1). Excessive load 2). Two-phase operation
-
06/13/2020
Technical status and development trend of refrigeration and air-conditioning compressors
Refrigeration machinery and air conditioning equipment play a very important role in the development of the national economy, the improvement of people's lives and the support of national defense equipment.
-
06/26/2020
What brand of refrigerator compressor is the best
Do you know what the most important parts of a refrigerator are? Of course, it is the compressor. The refrigerator can work normally because of it. It can be said that the compressor is the core component of the refrigerator.