Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.4 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.28...0.4 A |
Suitable for induction motors with P | 0.09 kW |
Instantaneous overcurrent releases | 5.2 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.235 kg |
Circuit breaker size S00 for motor protection, CLASS 10 A-release0.28...0.4 A
N-release 5.2 A Screw terminal Standard switchingcapacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 - +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.28 - 0.4
operating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value0.4 A
operating current
at AC-3 at 400 V rated value 0.4 A
operating power at AC-3
at 230 V rated value 60W
at 400 V rated value90 W
at 500 V rated value180 W
at 690 V rated value180 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 5.2 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value0.4 A
at 600 V rated value0.4 A
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V None required
at 500 V None required
at 690 V None required
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Siemens Circuit Breaker 3RV1011-0EA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV1121-0GA10
Siemens Circuit Breaker 5SY4104-7CC
Siemens Circuit Breaker 3RV2011-1GA20
Fuji Circuit Breaker EW50EBG-3P50A
Mitsubishi Circuit Breaker NF400-CP
Fuji Circuit Breaker SA203BM-3P200A
Fuji Circuit Breaker EW100EAG-3P075B
TRIAD Transformer VPT100-10000
Siemens Contactor 3RT2018-2XB41-2LA2
Littelfuse Fuse 142.6185.5106
HONGFA Relay HFE23-A-12-3SDT1-R
Yageo Resistor RSF2WSJT-62-470K
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SCHRACK Relay V23047-A1024-A511
HONGFA Relay HF18FF-A220-4Z1D
Fanuc Power Supply IC693PWR321Y
Recent related posts
-
06/23/2020
What is the solution of air conditioning not cooling
There are many reasons why the air conditioner is not cooling. For example, if the air conditioner refrigerant is insufficient, you can find a professional to add snow; secondly, it may be caused by the error of the air conditioner installation, such as the ventilation pipe is too long. It is recommended to shorten the length of the ventilation pipe; A lot of dust stains accumulate on the radiator and cause no cooling. It is recommended to clean the air conditioner.
-
07/31/2020
Five common problems of refrigeration system
Trouble phenomenon: The cooling effect of the whole machine is poor, the water outlet is only slightly cool, and the pressure on the high pressure side and the low pressure side are found to be low when checked with the manifold pressure gauge (under the normal speed of the compressor
-
09/01/2020
Brief Discussion on the Functions of Components of Skid-mounted Reciprocating Compressor Unit
Nowadays, most high-speed reciprocating compressors are assembled and complete sets in factories. They are pre-assembled to facilitate transportation and quickly establish contact with customers, greatly reducing installation time and costs...
-
09/11/2020
Provide compressed air without oil, water and dust
The drying effect is achieved through the principle of pressure swing adsorption. Not only can it be matched with a small air compressor, but it can also meet the needs of local users with special requirements behind the large air compressor, so as to avoid the high air quality requirements of individual points and the high configuration of the entire equipment to save investment.
-
08/13/2020
Compressor in the industrial chiller system produces wet stroke fault and troubleshooting
In the industrial chiller system, when the compressor sucks in wet steam, frost occurs on the cylinder wall, and the suction temperature and discharge temperature drop significantly. This is the wet stroke of the compressor, commonly known as frost.
-
09/16/2022
What is Hydraulic Pump? (Function, Types, Application&Selection Method)
The basic hydraulic system components include oil tank, hydraulic pump, control valve, oil cylinder, connecting pipe and relief valve.
-
06/14/2020
Screw compressor overhaul
Screw compressor overhaul Screw compressor overhaul, normal working condition of refrigeration system in operation: 1. The suction temperature of the compressor should be 5-15 ℃ higher than the evaporation temperature; 2. The discharge temperature 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱
-
08/05/2020
The purpose, method and choice of cold storage system defrosting
The purpose, method and choice of cold storage system defrosting
-
03/28/2024
High-Performance Drive Solutions: Innovation and Development of Servo Motors in Robotics
In recent years, robotic technology has been widely used in industrial production, service industries, medical care and other fields. The motion control of robots is the key to achieving various complex tasks.
-
11/02/2022
Detailed Classifications and Features of Electric Motors
Electric motors play an irreplaceable role in production, transmission and distribution. Each of them has their own structures, working principles, types of source power and applications.