Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 1 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.7...1 A |
Suitable for induction motors with P | 0.25 kW |
Instantaneous overcurrent releases | 13 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.233 kg |
Circuit breaker size S00 for motor protection, CLASS 10 A-release0.7...1 A
N-release 13 A Screw terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.7 - 1
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value0.5 A
operating current
at AC-3 at 400 V rated value 0.5 A
operating power at AC-3
at 230 V rated value 60 W
at 400 V rated value160 W
at 500 V rated value180 W
at 690 V rated value250 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 13 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value1 A
at 600 V rated value1A
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V gL/gG 10 A
at 500 V gL/gG 10 A
at 690 V gL/gG 10 A
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Siemens Circuit Breaker 3RV1011-0JA10
People who bought this item also viewed
Siemens Circuit Breaker 3VA1340-4EF32-0AA0
Siemens Circuit Breaker 3RV1021-1JA10
Siemens Circuit Breaker 5SL6304-7CC
Siemens Circuit Breaker 3RV1021-1JA15
GE Circuit Breaker GPS1BHAM 11-16A
Siemens Circuit Breaker 3RV1011-1EA10
TRIAD Transformer N-51X
Siemens Contactor 3TC5217-0BU0
CITEL Surge Protection Device DSM40-320
Siemens Fuse 3NA6 824-7
Mitsubishi Relay SRD-N8CX DC125V
Duelund Resistor CAST 2R4 ±5% 10W
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
COKERY Belt 2-11M975-JB
Beckhoff Terminal Box Module IP1002-B730
YUKEN Vane Pump PV2R33-116-136-F-REAA-41
Sanyo Denki Servo Drive 65BA030VDT15
KSK Oil SealTC(FKM)50X62X7
Recent related posts
-
09/09/2020
Compressor companies have caused the misunderstanding of killing, how many tricks have you hit
In recent years, many machinery manufacturing companies, including the compressor industry, have suffered unprecedented tests. Some are not adaptable due to the transformation of the economic system, and there are also "secret injuries" from the company’s own business strategy.
-
05/26/2022
Level of Safety Light Curtain?
In modern chemical plants, people work together with mechanical equipment. Mechanical equipment is becoming more and more automatic, and workers are more and more likely to be hurt.
-
09/06/2022
How to Select Overflow Valve
The nominal pressure of the overflow valve is determined by the operating pressure, the service temperature range of the safety valve is determined by the operating temperature
-
08/19/2020
What are the protection devices of industrial chillers
Industrial chiller is a kind of water cooling equipment that can provide constant temperature, constant current and constant pressure cooling equipment. The principle of the chiller is to inject a certain amount of water into the internal water tank of th ﰸ2 䀀
-
07/08/2023
Heat Pump Compressor Not Running: Common Issues and Solutions
A heat pump is an energy-efficient heating and cooling system that relies on the process of heat transfer to maintain comfortable indoor temperatures.
-
03/09/2022
Why is Your Refrigerator Start Relay Bad
Refrigerators have been necessary for people’s daily life and there are probably some problems with your refrigerators
-
08/18/2023
Solar Assisted Heat Pump: Definition, Working Principle and Benefits
Solar assisted heat pumps are gaining popularity as an eco-friendly alternative to traditional heating systems.
-
06/13/2020
Axial compressor
Axial compressors and centrifugal compressors are both speed type compressors and are called turbo compressors. The meaning of speed type compressors is that their working principle relies on the blades to work on the gas, and the flow speed of the gas ca 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥
-
09/17/2021
How to Replace Refrigerator Compressor
If the refrigerator compressor is broken and can no longer be repaired, you need to buy a new one to replace it. When replacing, you need to follow the correct steps.
-
01/09/2021
Comfortable Home Green Black Technology
Comfortable Home Green Black Technology Let me talk about the widely used green technology system: 1F ground source heat pump Renewable energy utilization technology, according to legend, it obtains shallow soil energy for heating and cooling, so t 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ԟ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ