Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 1.25 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.9...1.25 A |
Suitable for induction motors with P | 0.37 kW |
Instantaneous overcurrent releases | 16 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.353 kg |
Circuit breaker size S0 for motor protection CLASS 10 A-release0.9...1.25 A Short-circuit release 16 A
Screw terminal Standardswitching capacity !!! Phased-out product !!! Successor is SIRIUS3RV2 Preferred successor
type is 3RV2011-0KA10
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.8 W
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
protection class IP
on the front IP20
mechanical service life (switching cycles)
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica 100 000
continuous current rated value 1.25 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.9 - 0.25
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating current
at AC-3 at 400 V rated value 1.25 A
operating power at AC-3
at 400 V rated value 370 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 50022
height 97 mm width 45 mm depth 96 mm
Siemens Circuit Breaker 3RV1021-0KA10
People who bought this item also viewed
Fuji Circuit Breaker EW100EAG-3P063
Siemens Circuit Breaker 3RV2011-0EA10
Siemens Circuit Breaker 3RV1042-4KB10
Siemens Circuit Breaker 3RV1011-0EA10
Siemens Circuit Breaker 3RV1041-4LA10
Fuji Circuit Breaker EW32AAG-2P020B
Eaton Moeller Circuit Breaker LZMB1-A32
Fuji Circuit Breaker EW50RAG-3P32A
ABB Circuit Breaker 10068061
Block Transformer VC16/2/15
Moeller Contactor DILM65(380V50/60HZ)
OBO Surge Protection Device MCD 125-B NPE
Aupo Fuse BF73
Relpol Relay R4N-2014-23-1024-WTL
Yageo Resistor RC0805JR-074K7L
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Allen Bradley Servo Drive 1395-A65-D1-P12-P50
Copeland Compressor ZP137KSE-TFP-522
Festo Air Cylinder DSNU-20-110-P-A
PIZZATO Switch FL 979
Recent related posts
-
06/27/2020
Working principle of air compressor
An air compressor (air compressor) is a device used to compress gas. The structure of air compressor and water pump is similar. Most air compressors are reciprocating piston type, rotating blades or rotating screws. Centrifugal compressors are very large applications.
-
01/12/2021
Mitsubishi Heavy Industries air conditioning and Daikin which is better
Mitsubishi Heavy Industries and Daikin are both well-known Japanese companies. The following is a brief introduction to the background of the two companies: First, Daikin Air Conditioning is an old-brand industry in Japan. It has been the owner since 1924 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ي 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
01/02/2021
Mads Clausen - the founder of Danfoss
From just a single valve and an unquenchable desire to succeed, Danfoss founder, Mads Clausen, created a global business that still sets the standard for innovation today.
-
06/22/2020
What is the cause of refrigerator compressor not working
What is the cause of refrigerator compressor not working Ambient temperature is too low: it is more difficult to recover, the compressor cannot work for a long time, the compressor oil becomes thicker, and the lubrication performance will be worse; PTC starter failure: if the PTC starter is damaged, you can replace it Overload protector failure: failure occurs, replace it; compressor internal failure: determine that the compressor holds the shaft and replace it. <img src="{{media url="magefan_blog/What_is_the_cause_of_refrigerator_compressor_not_working.jpg"}}" alt="" />
-
06/28/2020
Hitachi compressor, the world's first
When choosing a home central air conditioner, many attentive consumers will compare the compressor technology of various brands. Because the compressor is the heart of the central air conditioner, the advanced nature of the compressor technology is directly related to the effectiveness and stability of the entire air conditioning system. It’s no surprise that consumers are more concerned about compressor technology. The editor here briefly introduces the advantages of Hitachi compressors.
-
06/25/2020
Comparison of characteristics of Hitachi inverter scroll compressors for household and commercial and vehicle air conditioning
Comparison of characteristics of Hitachi inverter scroll compressors for household and commercial and vehicle air conditioning Due to the different applications, Hitachi inverter scroll compressors have different characteristics.
-
09/05/2020
What is the composition of the often said air compressor station
For air compressors, especially screw air compressors, they cannot be used directly. It is also necessary to establish an air compressor station with corresponding post-processing equipment.
-
07/19/2020
Basic knowledge of refrigeration compressor
After shutting down, stop for at least 3 minutes before starting again to eliminate the pressure difference between the compressor inlet and outlet. Because in the case of a large pressure difference, the starting torque of the motor will increase, causing the current to rise to a certain level, the protector will act and the compressor cannot continue to run.
-
12/08/2022
How to Calculate the Service Life for Linear Guideways?
When the linear guideway is under load and moves, the surface of the ball track and the steel ball are constantly subjected to cyclic stress.
-
07/07/2020
Why defrost cold storage What are the ways to defrost
Why defrost cold storage What are the ways to defrost I. Overview: The frost on the surface of the evaporator in the cold storage hinders the conduction and distribution of the cooling capacity of the refrigeration evaporator (pipe), which ultimately affects the cooling effect.