Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 40 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 32...40 A |
Circuit breaker size S2 for motor protection, CLASS 10 A-release
14...20 A N-release 260 A screw terminal increased switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 14.5?W
at AC in hot operating state per pole 4.8?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
14?...?20?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 20?A
operating current
at AC-3
at 400 V rated value 20?A
operating power
at AC-3
at 230 V rated value 5?500?W
at 400 V rated value 7?500?W
at 500 V rated value 11?000?W
at 690 V rated value 15?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 10?kA
at 690 V rated value 5?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 18?kA
at AC at 690 V rated value 8?kA
response value current
of instantaneous short-circuit trip unit 260?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 20?A
at 600 V rated value 20?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 1.5?hp
at 230 V rated value 3?hp
for three-phase AC motor
at 200/208 V rated value 7.5?hp
at 220/230 V rated value 7.5?hp
at 460/480 V rated value 15?hp
at 575/600 V rated value 20?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 100
at 500 V 80
at 690 V 63
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Siemens Circuit Breaker 3RV2032-4BA15
People who bought this item also viewed
ABB Circuit Breaker GSH202 AC-C16
Siemens Circuit Breaker ED43B050
Siemens Circuit Breaker 3RV1021-4AA10
Siemens Circuit Breaker 3RV1011-0KA10
Siemens Circuit Breaker 3RV2011-0JA20
Mitsubishi Circuit Breaker NF125-HW
Schneider Circuit Breaker LV431940
Bel Signal Transformer DP-241-4-24
Lovato Contactor BF3800A
Littelfuse Fuse 0454004.MR
COTO Relay 9001-05-02
UniOhm Resistor 201007J0180T4E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TAKEX Sensor GTR3N
Yaskawa Servo Drive SJDE-01ANA-OY
IFM Sensor ID0014
ZIPPY Power Supply M1K-2C00V
CHELIC Air Cylinder JGD50*115
Recent related posts
-
09/08/2020
What environment will affect the operation of the air compressor
The surrounding environment of the air compressor will also have a significant impact on the operation of the air compressor. The following phenomena are mainly caused by the analysis of the cause of the failure caused by the bad surrounding environment, so the user should try to meet the standard requirements when installing the air compressor to deal with the surrounding environment .
-
08/17/2022
AC Motor: Types, Speed Control, Features & Uses
An <strong>AC motor</strong> is a device that converts AC electrical energy into mechanical energy. The AC motor is mainly composed of an electromagnet winding used to generate a magnetic field
-
07/07/2020
Overnight, refrigerant leaked light, guess where is the problem
Overnight, refrigerant leaked light, guess where is the problem After receiving notification from VIP customers, they went to a concrete mixing plant in the suburbs to repair an air conditioner.
-
09/15/2020
Advantages and applicable fields of silent oil-free air compressor
Introduction to the advantages of silent oil-free air compressors and applicable fields When it comes to air compressors, everyone seems to remember the roar of motors that have a great impact on our lives and work, and because of the shortcomings of high noise, the scope of use of air compressors has great limitations.
-
08/05/2022
FANUC Common Fault Alarm Analysis
1. The system alarm displays 9056, and the <a href=”url”>FANUC spindle amplifier</a> alarm code displays 56.
-
07/18/2020
Fault analysis and treatment of excessive oil consumption of the refrigeration compressor of piston chiller
Commonly used chillers are divided into piston type, screw type, centrifugal type, and vortex type chiller according to the type of refrigeration compressor used. Their evaporators and condensers generally use shell and tube heat exchangers, the throttling device uses thermal expansion valves, the refrigerant is freon
-
06/14/2020
Advantages of cascade cryogenic refrigeration system industrial chillers
Advantages of cascade cryogenic refrigeration system industrial chillers The cascade refrigeration system is a low-temperature refrigeration system that uses more than two refrigerants and combines them with a heat exchanger (condensation evaporator) in ﰸ2 䀀 ᅵ皥
-
09/11/2020
Hanbell screw compressor oil replacement operation specification
Maintenance and operation instructions for the refrigerating oil of the screw refrigerant compressor of Hanbell 1. The role of lubricating oil:
-
01/10/2022
How to Choose Pulse, Analog and Communication Control Modes of Servo Motor
There are three control modes of servo motor: pulse, analog and communication. In different application scenarios, how should we choose the control mode of the servo motor
-
03/15/2024
What Is a Servo Motor? Types of Servo Motors
In industrial applications, the most common motor is the servo motor. It is commonly used to drive motion axes to achieve high-precision positioning.