Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 40 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 28...40 A |
Circuit breaker size S3 for motor protection, CLASS 10 A-release
28...40 A N-release 520 A screw terminal Standard switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S3
size of contactor can be combined company-specific S3
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 23?W
at AC in hot operating state per pole 7.7?W
insulation voltage with degree of pollution 3 at AC
rated value
1?000?V
surge voltage resistance rated value 8?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 25?000
of auxiliary contacts typical 25?000
electrical endurance (switching cycles)
typical 25?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
28?...?40?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 40?A
operating current
at AC-3
at 400 V rated value 40?A
operating power
at AC-3
at 230 V rated value 11?000?W
at 400 V rated value 18?500?W
at 500 V rated value 22?000?W
at 690 V rated value 37?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
note 1
number of NO contacts for auxiliary contacts 1
note 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 30?kA
at 500 V rated value 6?kA
at 690 V rated value 3?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 65?kA
at AC at 500 V rated value 12?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 520?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 40?A
at 600 V rated value 40?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 3?hp
at 230 V rated value 7.5?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 15?hp
at 460/480 V rated value 30?hp
at 575/600 V rated value 40?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 165?mm
width 70?mm
depth 176?mm
Siemens Circuit Breaker 3RV2041-4FA15
People who bought this item also viewed
Fuji Circuit Breaker EW32AFC-2P015
Siemens Circuit Breaker 3RV2021-4EA10
Siemens Circuit Breaker 3RV1011-0CA15
Siemens Circuit Breaker 3RV1031-4AB10
Siemens Circuit Breaker 3RV1031-4BA10
Fuji Circuit Breaker BW50RAGU-3P015
Siemens Circuit Breaker 5SY4325-7
Siemens Circuit Breaker 3WL1240-2CB37-4GA2
TRIAD Transformer F48-250
Schneider Contactor LC1D11500E5C
DEHN Surge Protection Device BXT BAS
Fuji Fuse CR6L-100S
EOCR Relay DS3HELG-60N110 110V
UniOhm Resistor 25121WJ0335T4E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Air Cylinder DPDM-20-10-P-PA
NB Nippon Bearing Linear Guideway SYTS1085-D
GE Circuit Breaker FE250 3P 200A
Recent related posts
-
07/22/2020
The working principle of cooling and heating of air conditioning
In addition to the cooling function, the heating and cooling air conditioner also has the heating function. The biggest difference from a single-cooling air conditioner is that an electromagnetic four-way reversing valve is installed in the heating and cooling air conditioner.
-
09/08/2020
Different concepts of air compressor and compressor
Without understanding of air compressors and compressors, people often have a wrong idea: mistakenly think that air compressors are compressors. In fact, there is still a big difference between the two. Air compressors and compressors are actually two different mechanical products, although they have certain commonalities and connections.
-
06/29/2023
The Inner Workings of Inverter ACs: How They Save You Money and Keep You Comfortable
Air conditioning is an essential part of modern life, especially in hot and humid climates. However, traditional air conditioners can be very inefficient, consuming a lot of energy and driving up electricity bills.
-
09/29/2023
Heat Pump Clothes Dryer: Everything You Need to Know
Clothes dryers are a convenient appliance that saves time and effort when it comes to doing laundry. However, traditional clothes dryers can be not very energy-efficient.
-
10/05/2023
Freeze Drying vs Dehydration: Is a Freeze Dryer and a Dehydrator the Same Thing
When it comes to preserving food, there are a variety of methods that can be used. Two of the most common methods are freeze-drying and dehydrating.
-
01/11/2024
Common Faults of Cold Storage (with a List of Fault Repair Methods)
Cold storage is an indispensable and important facility in many industries. They play a key role in storing and preserving various products. However, even with the most sophisticated systems, cold storage can suffer from various failures.
-
01/31/2023
What is a Gear Reducer?
The gear reducer is an independent enclosed transmission gear between the prime mover and the machine, which is used to reduce the speed and increase the torque to meet the work needs.
-
09/19/2022
How Does a Hydraulic Pump Work?
In modern construction machinery, hydraulic working devices are basically inseparable.
-
06/14/2020
Fresh air system allows you to breathe fresh air at home for 24 hours
Fresh air system allows you to breathe fresh air at home for 24 hours In recent years, poor outdoor air quality has caused sensitive people to induce respiratory diseases;
-
06/20/2020
Working principle of scroll compressor_Characteristics of scroll compressor
Working principle of scroll compressor <img src="{{media url="Working_principle_of_scroll_compressor_Characteristics_of_scroll_compressor.jpg"}}" alt="" /> Scroll compressor is a kind of positive displacement compression compressor, the compression part is composed of movable scroll and static scroll. This includes many structural features that divert the flow of gas through the compressor housing to reduce entrained oil.