Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.63 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.45...0.63 A |
Circuit breaker size S00 for motor protection, CLASS 10 with
overload relay function A-release 0.45...0.63 A N-release 8.2 A screw
terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection with overload relay function
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5?W
at AC in hot operating state per pole 1.8?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
0.45?...?0.63?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 0.63?A
operating current
at AC-3
at 400 V rated value 0.63?A
operating power
at AC-3
at 230 V rated value 90?W
at 400 V rated value 180?W
at 500 V rated value 180?W
at 690 V rated value 250?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch laterally
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 1.5?A
at 230 V 1.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 100?kA
at 500 V rated value 100?kA
at 690 V rated value 100?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 100?kA
at AC at 690 V rated value 100?kA
response value current
of instantaneous short-circuit trip unit 8.2?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.63?A
at 600 V rated value 0.63?A
contact rating of auxiliary contacts according to UL C600 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gL/gG: 6 A, quick: 10 A
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 690 V gL/gG 6 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 65?mm
depth 97?mm
Siemens Circuit Breaker 3RV2111-0GA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV1031-4BA10
Siemens Circuit Breaker 3RV2011-1GA10
Siemens Circuit Breaker 3RV1011-0DA15
Siemens Circuit Breaker 3RV1021-4BA10
Siemens Circuit Breaker 3RV1021-4CA10
GE Circuit Breaker FG630 3P 630A
Siemens Circuit Breaker 3RV2021-4PA10
CHINT Transformer TDGC2J-60
Fuji Contactor SW-0RM
Ferraz Shawmut Fuse PC73GB69V315EF
LG LS Relay GTH-22/3 16-22A
UniOhm Resistor 25121WJ0115T4E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Cutler Hammer Circuit Breaker HFD2100
Recent related posts
-
08/20/2020
The reason why the compressor of industrial chiller cannot start
What is the reason why the industrial chiller cannot be started? The compressor is the core part of the industrial chiller. If it cannot be started, the entire unit cannot operate normally. When the compressor is started,
-
06/25/2020
Basic knowledge of air energy
At present, the most commonly used vapor compression heat pumps, compressors, evaporators, condensers, and throttle valves are the four main components. Other auxiliary components include fans, four-way valves, liquid storage tanks, gas-liquid separators, copper pipes, and Protectors and electronic control parts used to ensure the normal operation of the machine, etc. Direct-heating models also include a water flow regulating valve. Schematic diagram of commercial air source heat pump system
-
08/11/2020
Technology Refrigeration equipment system operation analysis and energy saving measures introduction
1.Economic analysis of refrigeration equipment system operation<br></br> The amount of cold produced by refrigeration equipment is directly related to the operating conditions of the system.
-
07/14/2020
What's wrong with the freezer not cooling
1. Test the power cord with an electric pen. The broken power cord of the freezer is also a cause of non-refrigeration. For this situation, we need to check whether it is a power problem. The general approach is to open the door and observe whether the lighting lamp in the box Light up. Look for signs of damage to the wires, such as being bitten by a mouse.
-
02/24/2020
Why is the air conditioner not cooling
1.Check whether the compressor is working normally. If the compressor is broken, the air conditioner cannot start normally and there will be no cooling effect. 2. There is not enough refrigerant in the air conditioner. At this time, you need to add Freon, and the time for adding Freon can be very long. 3. The air conditioner itself has quality problems and the electrical components have failed. In this case, you need to find a master to repair it.
-
12/13/2021
Get the Insights of Future Trends of HMI from Delta HMI
HMI is the device connects the user and the machinery system. It is the medium of information transfer and exchange between people and machines. Since the first button switch was developed, man-machine interface monitoring system has become an essential part of industrial production.
-
06/13/2020
Characteristics of magnetic suspension refrigeration compressor
Characteristics of magnetic suspension refrigeration compressor 1. High operating efficiency: 2. No need for lubricating oil, maintenance cost is 50% lower than oil-containing compressor: 3. Ultra-light body design: 4. Super quiet operation process: ﰸ2 䀀 ᅵ皥
-
07/02/2020
Introduction of the models such as the MT-100 and other hermetic compressors
Introduction of the models such as the MT-100 and other hermetic compressors The picture shows the fully enclosed compressor MT-100, which is installed by the customer. Meiyou Le Maneurop hermetic compressor detailed introduction;
-
06/21/2020
Types of steam compressors_selection of steam compressors
Types of steam compressors_selection of steam compressors Types of steam compressors<img src="{{media url="Types_of_steam_compressors_selection_of_steam_compressors.jpg"}}" alt="" /> 1. Single-stage high-speed centrifugal blower This type of steam compressor is a relatively common steam compressor on the market. It can have a large air volume and pressure and can meet the needs of many working conditions. The single-stage high-speed centrifugal blower is designed with a ternary flow theory, and the whole structure of the fan is compact , And the technology is relatively mature. 2. Roots type steam compressor
-
06/13/2020
Tube heat exchanger
The casing heat exchanger is a carrier that transfers part of the heat of the hot fluid to the water. It uses high-efficiency screw-shaped copper tubes and wraps the treated galvanized steel pipes to realize the process of refrigerant water-filling, allow 器2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ