Okmarts Siemens Circuit Breaker 3VL5750-2DC36-0AA0 Siemens Circuit Breaker 3VL5750-2DC36-0AA0, okmarts Online Average rating: 4.6, based on 89 reviews
Siemens Circuit Breaker 3VL5750-1DC36-0AC1

Siemens Circuit Breaker 3VL5750-1DC36-0AC1

Siemens Circuit Breaker 3VL5763-1AA36-0AA0

Siemens Circuit Breaker 3VL5763-1AA36-0AA0

Siemens Circuit Breaker 3VL5750-2DC36-0AA0

Siemens Circuit Breaker 3VL5750-2DC36-0AA0 VL630H high breaking capacity Icu=70kA, 415V AC 3- pole, line protection trip unit TM, LI In=500A, rated current IR=400...500A, overload protection, II=2500...5000A, short-circuit protection without auxiliary release without auxiliary/alarm switch
$1,523.44
Availability: In stock
SKU
SSCB-1096
* Shipping calculated at checkout.

Packing and shipping

Packaging Regulation :

Wooden box

Delivery time :

7~14 days(About)

Conditions :

New and Genuine

The Siemens Circuit Breaker is high quality!
circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 3-
pole, line protection trip unit TM, LI In=500A, rated current
IR=400...500A, overload protection, II=2500...5000A, short-circuit
protection without auxiliary release without auxiliary/alarm switch
Model
type of the driving mechanism / motor drive No
design of the overcurrent release TM
General technical data
number of poles 3
size of the circuit-breaker 3VL5
mechanical service life (switching cycles) / typical 10 000
Current
continuous current / rated value 500 A
derating temperature / for the rated value of the
continuous current
50 degrees centigrade
adjustable current response value current
of the current-dependent overload release / fullscale value
500 A
of instantaneous short-circuit trip unit / initial
value
2 500 A
of instantaneous short-circuit trip unit / full-scale
value
5 000 A
Main circuit
operating frequency
1 / rated value 50 Hz
2 / rated value 60 Hz
operational current
at 40 degrees centigrade / rated value 500 A
at 50 degrees centigrade / rated value 500 A
at 55 degrees centigrade / rated value 465 A
at 60 degrees centigrade / rated value 465 A
at 65 degrees centigrade / rated value 430 A
at 70 degrees centigrade / rated value 430 A
Auxiliary circuit
number of CO contacts / for auxiliary contacts 0
number of NC contacts / for auxiliary contacts 0
number of NO contacts / for auxiliary contacts 0
Short circuit
breaking capacity operating short-circuit current (Ics)
at 240 V / rated value 75 kA
at 415 V / rated value 70 kA
at 500 V / rated value 30 kA
at 690 V / rated value 10 kA
breaking capacity maximum short-circuit current (Icu)
at 240 V / rated value 100 kA
at 415 V / rated value 70 kA
at 440 V / rated value 50 kA
at 480 V / acc. to NEMA / rated value 50 kA
at 500 V / rated value 40 kA
at 600 V / acc. to NEMA / rated value 30 kA
at 690 V / rated value 20 kA
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account