SQUARE D Circuit Breaker BGA36125
- Specifications
- Q&A
- Reviews
Mitsubishi Circuit Breaker NF250-CV
Siemens Circuit Breaker 5SY4310-7CC
Block Transformer STEU500/23
TENGEN Contactor CJT1-100A 380V
Conquer Fuse MST T2A300V
IXYS Relay CPC1330GR
UniOhm Resistor 201007J0682T4E
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
JANUS Overflow Valve RVB-03-LB
CFW Oil Seal BA 12*32*7
AIR SUPPLY Air Compressor 2X1500W-50L
MURATA Capacitor NFM21HC105R1C3D
DEKA Battery 8G24
08/14/2020
To ensure that the condenser has a higher heat transfer coefficient, it is necessary to reduce the resistance in the system. There are three ways to achieve this goal.
06/14/2020
Analysis of the current status of refrigeration compressor technology development
06/14/2020
Mechanical Reliability-up (Mechanical Drive Steam Turbines)
09/06/2020
Energy saving principle After the compressed air is discharged from the compressor, it needs to be transported to the application place through the air tank and pipeline. In the field of use, there are problems with gas storage tanks and pipelines
07/13/2020
Danfoss 40 hp big blue compressor Today I will introduce to you Danfoss CH485 compressor, CH485 40 ton compressor is not only compact but also integrates many innovations. The CH485 compressor has the following characteristics in terms of protection level and improved efficiency:
06/24/2020
Turn off the power supply of the air conditioner first; if all the light leaks, then you must evacuate before adding it; find the thick tube under the outdoor unit and add fluorine from here; you need to install the pressure gauge when adding fluorine Generally, it can be stopped at about 5 pressures; the temperature needs to be turned to the lowest when turning on the machine, and observe for about half an hour.
06/14/2020
Can an inverter air conditioner achieve first-class energy efficiency without an electronic expansion valve Inverter air-conditioning units do not use electronic expansion valve throttling, their own operational safety will deteriorate, and there is no w 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧
08/07/2020
1. Chilled water pump:<br></br> In the chilled water loop, a device that drives water to circulate. The end of the air-conditioned room (such as fan coil, air handling unit, etc.)
07/01/2020
Analysis of main characteristics of Feixun series Copeland compressors The main features of Copeland Compressor Feixun series are as follows: 1. The main features of Feixun compressor: ① maintainability is stronger; ② all parts can be disassembled and replaced; ③ main components are installed along the axis.
05/11/2022
Whether there is a fault in the indoor and outdoor units can be known by the access code of the remote control, the content of the green LED