There is no price at present, you can Request a Quote
Power: 9.5KW
Power: 380V/440V-50HZ/60HZ
Cylinder diameter (mm): 65
Stroke (mm): 55
Number of cylinders: 4
Exhaust volume: 63.5m3/h
Foot mounting size: 305mmx381mm
Dimensions (mm): length 688 width 456 height 449
Suction pipe inner diameter (mm): 54
Exhaust pipe inner diameter (mm): 28
Oil charge (liter): 4
Suitable for refrigerant: R12 R22 R502 We can also provide the following models
GUD80295VWYB5-2
GSD80485VBR5-1
GTD60235VLB5-2
GSD80182VAYB432
GUD80120VLYB632
GYD60120VAYR3-1
GYD80182VLYR632
GSU80421VLR2-1
GMD60421VBYB632
GMD80120VBR2
GTD80154VLR2
GTD60485VBB2-2
GMD80295VBR5
GED80295VAYR3
GYD60137VBR3-1
GTD60137VLYR332
GED60485VWR2-1
GTD60137VLB2-1
4VES-10-40S
GED80120VAYR5
GED60182VBB5-1
GUD60235VAYB4-2
GMD80182VAB3-1
GMD60154VBYR532
GMD80385VWR6
GTU60154VLYB4-1
GTD60137VBB5
F204H/4FES-3-40S
GYD80137VBYB3-1
GSD80385VAYB432
GUD80154VLYR2
GUD80385VLB432
GMD60154VLYB5-1
GSD80235VAR632
GYD80385VLR3-2
GTD80137VLYB3-1
GED80385VBR232
GYD60120VLR3-2
GED80120VAB5-2
GTD80120VBB332
GYD60182VAR2
GUU60154VLYB232
GTD60120VBR3-2
GSU80385VLB3-1
GSD60154VBB332
GSD80154VAYR232
GSD80485VAB332
GMD60137VAYR232
GED80235VWYB4
GMD80421VLR2
GMD60235VLB3
GTD60235VBB5-1
GSD80120VAR532
GSU60182VLB2-1
GTU80295VLYR4
GED80120VWYB4-1
GYU60235VLYB5-1
GUD60385VLYB432
HSN6461-50-40D
2MSL-07K
GUD60385VBYR2-2
GYD80485VLR432
GSD60182VB
4TE-12.F4Y-40S
GSD80235VBR532
GMD60235VAYR5
GSD60385VAB2-1
GSD80485VAR4-1
GUD80235VAR432
GYD60421VBB2-1
GYU80295VLR2-2
GTD80120VBB4-2
For more information,please contact us freely
Bitzer Compressor 4J-13.2Y-40P
There is no price at present, you can Request a Quote
People who bought this item also viewed
Bitzer Compressor 6H-35.2
Bitzer Compressor 4NCS-20.2-40P
Bitzer Compressor 4WBF-5.2
Bitzer Compressor 4DC-7.2-40P
Bristol Compressor H2EB243ABKA
Danfoss Compressor MTZ100HS4VE
LG Compressor GK134K
Daikin Compressor 1GDY23AXD
Block Transformer VB 0.35/2/12
Emerson Alco Expansion Valve TCLE2HZ
TENGEN Contactor CJT1-20A 220V
Sanyo Denki Fan 109BC24GC7-1
OLI-WOLONG Electric Motor MVE40/15
PARKER Filter 925945
EMERSON Sight Glass AMI-1TT9
DAIKIN Expansion Valve Coil RXN435KC
VISHAY Capacitor 160V 0.047UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Yaskawa Servo Motor SGMGH-13ACA6C
Yaskawa Servo Motor SGMAV-01ADA-SB11
OUYIPU Vane Pump 150T-94+S
PIZZATO Switch FR 693-DK70
SIEMENS Capacitor B43540-B9227-M2
KCL Vane Pump SVQ435-136
Recent related posts
-
07/14/2020
Compressor 9 types of faults and hazard analysis are all here! ! !
Compressor 9 types of faults and hazard analysis are all here! ! ! 1. Common faults of compressor — start with liquid Starting with fluid is a problem that easily occurs when the machine is stopped. During shutdown, the refrigerant will migrate from the system back to the compressor and deposit in the lubricant.
-
07/17/2020
refrigerating system
4.1 Pressure vessels and pipelines are often contacted by refrigeration and air-conditioning technicians;; components of various systems; for example, placing an R--22 refrigerant storage tank on the rear panel of a car with a common barrier; The hot summer sun can make the temperature of the steel pipe reach 110F; the total area of
-
08/16/2020
What are the tasks that water-cooled chillers need to perform regularly
When using a water-cooled chiller, due to environmental or water quality issues, which will affect the normal operation of the equipment, it is necessary to perform some work on the water-cooled chiller regularly to maintain a stable working state and reduce the occurrence of failures.
-
02/08/2022
Why Refrigeration System Clogged
The blockages in the refrigeration system include ice, dust, oil and welding blockage, etc.
-
09/27/2023
Industrial Water Chiller Repair: Troubleshooting and Maintenance Tips
An industrial water chiller is a critical component in many manufacturing and industrial processes. It is responsible for cooling various types of equipment, which helps to prevent overheating and maintain optimal performance.
-
09/06/2020
What happens if the water-cooled air compressor is short of water
The cooling methods of screw air compressors are mainly divided into two types: air-cooled and water-cooled. Air-cooled air compressors are a relatively common cooling method and are used in small and medium-sized air compressors.
-
06/29/2023
The Inner Workings of Inverter ACs: How They Save You Money and Keep You Comfortable
Air conditioning is an essential part of modern life, especially in hot and humid climates. However, traditional air conditioners can be very inefficient, consuming a lot of energy and driving up electricity bills.
-
07/23/2020
How to reduce the discharge temperature of refrigeration compressor
The refrigeration compressor is the core and heart of the refrigeration system. The capacity and characteristics of the compressor lead to the capacity and characteristics of the refrigeration system. In a sense, the design and matching of the refrigeration system is to reflect the capacity of the compressor.
-
11/19/2023
Difference in 2 Pin, 3 Pin and 4 Pin Computer Fans: Which is better?
If a computer does not have a radiator, its internal temperature will be infinitely high, and eventually the hardware will be burned directly. Whether it is for the CPU, graphics card, chassis, or power supply, heat dissipation is required.
-
08/19/2020
The impact of excessive or small pump flow on the chiller
The chiller may have various types of failures. Why does the water pump fail with too much or too little flow?<br></br> In fact, whether the flow of the water pump is too large or too small, it will have a certain impact on the operation of the chiller, so it is not a good thing that the flow is too large or too small.