There is no price at present, you can Request a Quote
Body Type | CR Compressor |
Product Type | Copelaweld |
App | AC |
Capacity BTU/HR | 57000 |
EER BTU/WH | 10.1 |
Freq | 60Hz |
Phase | 3Ph |
Voltage | 380/460 |
Ref | 22 |
Copeland Compressor CRL3-0350-TFA-460
There is no price at present, you can Request a Quote
People who bought this item also viewed
Sanyo Compressor C-RN113H3C
Mitsubishi Compressor TB33YLLMC
Tecumseh Compressor TRK5512Y
Copeland Compressor DXLP-15X-EWL
Copeland Compressor CR53KQ-TFD-267RM
Copeland Compressor ZR190KC-TFD-551
Copeland Compressor ZR47KH-TFD-522
Hitachi Compressor TH420RV-C9EU1
GMCC Compressor PA185M2C-4FT2
Bitzer Compressor 4DC-5.2-40S
Bristol Compressor H2EB223ABK
COOPER Transformer CMS3-9-R
Emerson Alco Expansion Valve AA1/4SZ
TENGEN Contactor TGC1-2501 380V
ADDA Fan AD0812US-C70
Shinano Kenshi Electric Motor SST56C3200
Baldwin Filter RS4862
Danfoss Sight Glass SGR 014-0006
ELNA Capacitor 100V 20000UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
FTDI IC FT231XS-U
Sanyo Denki Fan 109P0412M702
RESUN Water Pump Penguin-8500
Nedfon Fan KTJ(D)-22-15-4C
MINDMAN Air Cylinder MCQV2-11-40-450
Recent related posts
-
07/01/2020
Several advantages of screw compressor
Several advantages of screw compressor In the cold storage installation, the choice of refrigerator is to choose to use screw machine or piston machine. The use of screw machines is gradually surpassing the share of the original piston machines.
-
05/11/2022
What is PLC?
Programmable logic controller (PLC) is a digital operation electronic system specially designed for application in industrial environment.
-
03/10/2022
Why is Your Refrigerator Start Relay Bad
Refrigerators have been necessary for people’s daily life and there are probably some problems with your refrigerators
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/17/2022
VFD Types And Applications?
Variable Frequency Drive (VFD) can be classified according to the following generic topologies
-
09/15/2020
Screw machine cleaning agent and protective agent and information
Synthetic cleaning oil, environmentally friendly product, powerful cleaning function and lubrication.
-
06/14/2020
How much future does using water as refrigerant
How much future does using water as refrigerant Refrigeration technology is always developing in the direction of high efficiency and environmental protection, but is it very futuristic to use water as a refrigerant?
-
06/29/2020
Semi-closed piston refrigeration compressor 4SJH-3000
Semi-closed piston refrigeration compressor 4SJH-3000 Features of semi-hermetic piston compressor 4SJH-3000: 1. Light in size and small in space 2. Suitable for R12, R22 and R502, with a wide range of applications
-
07/09/2020
Air Compressor Market in APAC – Industry Analysis and Growth Forecast to 2024
Asia Air Compressor Market ASEAN air compressor market size is expected to reach $1.13 billion by 2024, registering a CAGR of 3.6% during the forecast period. The major factors stimulating the market growth includes growing automotive industry and increasing investments in construction industry in the region.
-
06/22/2020
Which refrigerator is better
The two cooling methods of the refrigerator are good. From the perspective of defrosting, the air-cooled refrigerator will perform better, because the air-cooled refrigerator uses forced air convection to cool the temperature. It reaches the expected temperature, and it is not easy to frost. The direct-cooled refrigerator absorbs heat by the evaporator to reduce the temperature, and it is easy to condense the frost.<img src="{{media url="magefan_blog/Which_refrigerator_is_better.jpg"}}" alt="" />