Daikin Compressor JT100GCVDKW@SB
People who bought this item also viewed
Bristol Compressor H79B35UABHA
Copeland Compressor ZMD18KVE-TFD-277
Copeland Compressor CF09K6E-TF5-247
Daikin Compressor JT160BCB-YIL
Daikin Compressor 1YC23HXD
Daikin Compressor JT95BCBY1L
Daikin Compressor JT160BCBY1L
Daikin Compressor 1YC23AVXD
Danfoss Compressor MTZ36JG5AVE
Huaguang Compressor ETA150L
Bristol Compressor H23A383ABKA
TRIAD Transformer FD4-36
Danfoss Expansion Valve 042H2026
Togami Contactor CLK-15J40-S642C
Sanyo Denki Fan 9GV0912P1F03
LIMING Electric Motor SV13-20-15
Baldwin Filter PT8370MPG
Danfoss Sight Glass SG4S
YORK Expansion Valve Coil S436
AVX Capacitor 100V 0.1UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Fuji Contactor SC-E1PH-C
Meas Transmitter MSP-300-100-P-2-N-1
Kwangwoo KW Encoder RIB-50-0360ZT
Baumer Sensor FHDK 10P1101
Recent related posts
-
08/30/2021
How to Fix a Refrigerator Compressor?
The refrigerator compressor is the core of a refrigerator and achieves the cooling effect. Due to the frequent use of the refrigerator
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/14/2020
Compressor common fault handling
Compressor common fault handling Foam when starting with liquid When the air-cooled compressor is started, the phenomenon that the lubricating oil in the crankcase blisters violently is called liquid start. The basic reason for starting with liquid is 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱
-
07/02/2020
The compressor lacks oil, so the harm is so great!
The compressor lacks oil, so the harm is so great! Compressors are complex machines that operate at high speeds. Ensuring adequate lubrication of moving parts such as compressor crankshafts, bearings, connecting rods, and pistons is the basic requirement for maintaining normal operation of the machine.
-
10/29/2022
What is a Servo Drive
Servo drive, also known as "servo controller" and "servo amplifier", is a controller used to control servo motors, and its function is similar to that of frequency converters used for ordinary AC motor.
-
07/25/2020
90% of the compressor burns down due to these reasons (Refrigeration Oil)
The common faults of compressors mainly include the following three types: 1. Motor burns; 2. Oil shortage caused by refrigerating oil; 3. Liquid shock.
-
08/23/2022
Ways to Increase Stepper Motor Torque and Select Stepper Motor
Reduce the number of turns to reduce inductance L: select the motor with small inductance L from the standard products of the motor manufacturers, the rated current will increase.
-
08/15/2022
Top 10 Brands of Linear Motors
There are many brands of linear motors in the world. The following are some well-known brands of linear motors from countries and regions like Europe, America, Japan, Asia, etc. Hope it will be helpful to you.
-
01/29/2022
3 Reasons for Using Pressure Transmitters in HVAC Systems
Transmitters play an indispensable role in most applications in HVAC (Heating, ventilation, and air conditioning) systems, which can maintain a suitable indoor temperature
-
09/10/2020
Afternoon tea problems often exist in air conditioning design
The author of okmarts.com came into contact with the HVAC engineering design of some design institutes, and compared the "Code for Design of Heating, Ventilation and Air Conditioning"