Product Display
Product Description |
Parameter |
||
Brand: |
Electrolux Cubigel |
Voltage: |
220-240V 50Hz |
Refrigerant: |
R410a |
Displacement: |
8.10cm³ |
Model: |
MLY60LA |
Horsepower: |
1/4HP |
Origin: |
Sweden |
Application: |
LBP |
Specifications: |
Brand new |
Cooling capacity: |
W 276 COP 0.91 |
Type: |
Refrigeration compressor |
|
350kcal/h COP1.28 |
Application range: |
Refrigeration parts |
|
|
Material: |
Stainless steel |
|
|
Product Media
Installation Process
1. Check whether the refrigerating oil of the original compressor is too dirty. If the oil is too dirty, the system must be cleaned with nitrogen and the dry filter must be replaced.
2. Check whether the contacts of the compressor operation control AC contactor are stuck or have poor contact, causing the compressor to run out of phase. If the compressor is damaged in the coil winding, the AC contactor of the same model must be replaced.
3. Check and protect the circuit. The high and low pressure switch is in the closed state in the normal refrigerant compression state, the high pressure limit is less than or equal to 2.2Mpa, and the low pressure is more than or equal to 0.28Mpa.
4. Check whether the radiator is too dirty and must be cleaned.
5. Check whether the original equipment has refrigerant pressure, and repair it if the refrigerant is leaking.
1. Disconnect the power supply.
2. Disassemble the compressor and check its old compressor.
3. Nitrogen cleaning system, steps, disassemble the filter and blow in nitrogen from the inlet of the radiator, discharge from the outlet of the radiator, then blow in from the inlet of the filter, release from the return pipe of the compressor, and repeat cleaning several times.
4. Install the new compressor and weld the new filter.
5. Use nitrogen to pressure, 2.0Mpa pressure for leak detection for 30 minutes.
6. Circuit check and replace damaged parts, check power supply and control circuit.
7. Clean the radiator.
8. Vent the nitrogen and evacuate for 30 minutes.
9. Add the same type of refrigerant
10. Power-on debugging, check the compressor current and voltage, the normal pressure of the refrigerant, high pressure 1.7Mpa, low pressure 0.45Mpa, the refrigerant charge is expected to be 0.7kg/hp (10-30hp).
Packing & Shipping
Q: What means of transportation?
A: It can be shipped by air to the nearest international airport or by courier like DHL, TNT to your address; if it's not urgently required, they can also be shipped by sea to the nearest sea port.
Q: How long is your delivery time?
A: Usually, if it is in stock, it will take 5 to 10 days. Or, if there is no stock, it is 15-20 days, depending on the quantity.
Electrolux Co., Ltd. (Swedish: AB Electrolux, often referred to as Electrolux), referred to as Electrolux, is a Swedish multinational manufacturer of household appliances, headquartered in Stockholm [2]. The company continues to rank second in the number of sales units in the global home appliance industry (behind Whirlpool) and the number one in the global sales of commercial laundry laundry equipment [3].
Electrolux Cubigel Compressor MLY60LA
People who bought this item also viewed
Electrolux Cubigel Compressor S22TN
Electrolux Cubigel Compressor GH12TB
Electrolux Cubigel Compressor GU45TG
Electrolux Cubigel Compressor MPT12LA
Danfoss Compressor SY300A4CBM
Hitachi Compressor 303DH-50C2
GMCC Compressor YH480X3CS-4MUC1
Hitachi Compressor SHZ83LC4-E
TOGI Transformer TRP300-42Y
Danfoss Expansion Valve 067N6020
Siemens Contactor 3RT1054-1NP36-3PA0
Makita Fan Heat Gun HG5012
GTR Electric Motor FGN-15M-360-T40W
Danfoss Sight Glass SGP16SI
PHILIPS Capacitor 043 47UF 350V
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HENGSTLER Encoder RI58-O/50ES.41KJ
SuperRed Fan CHA8012BS
TENGEN Contactor CJT1-100A 36V
Mitsubishi Servo Motor HA-FE053
Baumer Sensor FVDK 12P6501/S35A
Panasonic Servo Drive MDDA153D1A
Siemens Contactor 3RT2016-1BB41
Recent related posts
-
05/25/2022
How to Install The Safety Light Curtain?
In order to ensure the normal operation and the safety of operators, we must install the safety light curtain according to the correct methods and steps.
-
09/13/2022
Differences between a Sensor and an Actuator
A sensor is a detection device that can sense the measured information, and can transform the sensed information into electrical signals or other required forms of information output according to certain rules to meet the requirements of information transmission
-
04/07/2022
Why Does The Fan Keep Running on My Air Conditioner?
Today, the air conditioning, as an electrical appliance that can adjust the temperature and make people feel cool is welcomed and loved by many people.
-
12/21/2022
Classifications and Features of Optical Fiber Amplifiers
An optical fiber amplifier, abbreviated as OFA, refers to a new type of all-optical amplifier used in optical fiber communication lines to achieve signal amplification.
-
06/14/2020
Screw compressor working principle and structure analysis
1. Features of screw compressor The screw-type refrigeration compressor has a simple structure and a small number of parts.
-
06/15/2022
How to Select a HMI?
There are three basic types of HMIs: the pushbutton replacer, the data handler, and the overseer.
-
07/30/2021
Where will Computer Numerical Control Machines Go?
At present, the development of Computer Numerical Control (CNC) machines with each passing day, characteristics of high-speed
-
07/04/2023
Don't Sweat It: How to Troubleshoot and Fix an AC Blowing Warm Air
When the weather gets hot, there's nothing more frustrating than an air conditioning unit that blows warm air. Not only is it uncomfortable, but it can also be a sign of a more serious problem with your AC system.
-
09/02/2020
7 reasons for high oil consumption of air compressors
Run oil In our daily work, we often encounter the problem of running oil in air compressors. In addition to the quality of the oil content, what other reasons can cause running oil? Engineers have summarized several reasons that can cause running oil in practice. The following okmarts .com share with you.
-
07/08/2020
How to solve the problem of poor oil return of screw chiller
1. What is the cause of the poor oil return of the screw chiller? Generally speaking, the reason for the poor oil return of the screw chiller is mainly due to the phenomenon of the gas mixture of lubricating oil and refrigerant during the operation. Specifically, in the operation of the refrigeration system, encountering the miscibility of the refrigerant and the refrigerator lubricating oil will cause the lubricant in the refrigeration compressor to run and the refrigerant will be discharged into the condenser in the form of gas mist and droplets.