Series | KH Series |
Type | Rotary Compressor |
Refrigerant | R22 |
Phase | 1PH |
Volt | 220-240V |
Hz | 50Hz |
Mitsubishi Compressor KH145VHFA
People who bought this item also viewed
Copeland Compressor ZB76K5E-TFC-260
Sanyo Compressor C-RN113H3C
Tecumseh Compressor TRK5480Y
Mitsubishi Compressor SNB130FGBHT
Mitsubishi Compressor AN66YQLMT
Mitsubishi Compressor ANE42FPFMT
Daikin Compressor JT95B-Y1L
LG Compressor QK222JBA
Bitzer Compressor 2GC-2.2Y
Bitzer Compressor 4T-12.2
TRIAD Transformer F48-050-C2
Danfoss Expansion Valve 068U2072
Sanyo Denki Fan 9LG0812H4001
TRANSTECNO Electric Motor MS71M2-4
LEEMIN Filter HX-63-20Q
Danfoss Sight Glass SGP10S
Sanyo Capacitor 25V 470UF 10×5
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Transmitter 7ML5033-2BA10-1A
TYCO Relay 8-1393144-6
KEMET Capacitor TRJB105K035RNJ
CKD Air Cylinder CMK2-C-00-40-300
Recent related posts
-
09/13/2022
Dealing with Actuator Failures: Common Causes and Solutions
The actuator device is a combination of the actuator part and the control valve in automatic control system.
-
06/22/2020
What to do if the air conditioner is not cooling
Air conditioning does not refrigerate mainly from the following aspects to solve: 1, regular cleaning and maintenance of air-conditioning outside machine. 2. Replace the old air conditioner that has exceeded the service life. 3. Check whether the copper pipes of the indoor and outdoor units of the air conditioner are too long. 4. Check whether the power of the air conditioner matches the indoor space. 5. Check whether the installation environment of the air conditioner is suitable. 6. Replenish refrigerant. <img src="{{media url="magefan_blog/What_to_do_if_the_air_conditioner_is_not_cooling.jpg"}}" alt="" />
-
12/21/2023
AC Fan Won't Turn off (Troubleshooting Guide)
The air conditioning system can be a true lifesaver during sweltering summers and chilling winters, providing comfort and respite from extreme temperatures.
-
08/17/2020
What are the effects of water quality on water-cooled chillers
If the cooling performance of water-cooled chillers is to be kept in a stable state, very strict requirements on the water source are required. In the daily use of chillers, if the company does not pay enough attention to the quality of the water source
-
01/25/2022
New Type of Pneumatic Pressure Transmitters - Working Principle & Features
The new type of anti-vibration pneumatic pressure transmitter is used with the BOP (blowout preventer) and the throttle manifold control box for oil and petroleum products.
-
06/30/2022
Types of Check Valve
Depending on the design of the check valve, they will operate slightly differently. The most common check valve is a spring loaded in-line check valve, however, we will discuss multiple types below.
-
08/17/2020
Temperature has a great influence on refrigeration and air-conditioning systems, don’t you know
The relevant temperature of the components of the refrigeration and air-conditioning system has a normal temperature range, and it is an abnormal state if it exceeds this range.
-
09/10/2020
The formation and harm of carbon deposits in air compressor
The reasons for the formation of carbon deposits in air compressors are more complicated. In terms of air compressor oil lubrication, the main reason is that the oil used in the internal lubrication system of the air compressor is often in the form of mist and high temperature, high pressure, high oxygen partial pressure air and metal The contact of the catalyst causes the air compressor oil to rapidly oxidize and deteriorate.
-
06/20/2020
Structure diagram of single vane compressor_Main features of single vane compressor
The basic structure and working principle of single slide compressor.<img src="{{media url="Structure_diagram_of_single_vane_compressor_Main_features_of_single_vane_compressor.jpg"}}" alt="" /> Single sliding vane compressor is also called scraper compressor or rolling rotor compressor. Its structure is shown in Figure 3-7. A cylindrical eccentric rotor (also called a piston) is installed in the cylinder, and the center of rotation of the rotor coincides with the center of the cylinder. In the middle of the upper part of the cylinder, a scraper that can slide up and down is installed. Due to the force of the spring,<img src="{{media url="Structure_diagram_of_single_vane_compressor_Main_features_of_single_vane_compressor2.jpg"}}" alt="" />
-
08/02/2020
How to determine the refrigerant leakage of the air conditioning system Only need these six steps
Shut down and unplug the air conditioner (to prevent danger during the inspection process), and connect a pressure gauge to the large valve. Observe the static pressure.