Series | RE Series |
Type | Rotary Compressor |
Refrigerant | R407C |
Phase | 1PH |
Volt | 208-230V |
Hz | 60Hz |
Mitsubishi Compressor RE277NRAMT
People who bought this item also viewed
Copeland Compressor ZMD26KVE-TFD-984
Tecumseh Compressor RKA5512YXD
Sanyo Compressor C-7RVN153HOW
Mitsubishi Compressor AN66YQLMT
Mitsubishi Compressor SNB130FGBHT
Mitsubishi Compressor BEH82YEDMT
Hitachi Compressor ATL232SDNC9AUA
Danfoss Compressor MTZ32JF5AVE
Panasonic Compressor C-SBN453H8G
Sanyo Compressor C-SC673H8H
SWALLOW Transformer SC21-200E
Emerson Alco Expansion Valve TCLE7SW
Siemens Contactor 3RT1064-6LA06
Sanyo Denki Fan 9GV0412P3J03-A04
LIMING Electric Motor CM09IA40TJ-P
PARKER Filter 937406Q
Danfoss Sight Glass SG16N
ETN Capacitor 25F 3V
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PARKER Filter FBO60338
TRIAD Transformer F-279U
AirTAC Air Cylinder SCF63X1000S
Ferraz Shawmut Fuse PC73GB69V400EF
Omron Sensor E3S-5LB41
Protechnic Fan MGA8024HB-O38
Recent related posts
-
07/23/2020
Analysis of common failure causes of hermetic refrigeration compressors
1. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.<br></br>
-
07/01/2020
What causes the exhaust temperature of the refrigeration compressor to be too high
What causes the exhaust temperature of the refrigeration compressor to be too high Refrigeration compressor is a kind of equipment commonly used in air conditioning and refrigeration. Without it, the air conditioner cannot be cooled normally. However, refrigeration compressors often encounter many problems in normal use. For example, the exhaust steam temperature is too high.
-
06/14/2020
The correct use of car air conditioners, to avoid misunderstandings!
The correct use of car air conditioners, to avoid misunderstandings! Whether it is cooling in summer or heating in winter, many car owners turn on the "air conditioning mode" while driving.
-
01/17/2023
How does Variable Valve Timing Work?
The valve timing system of a traditional engine is a mechanical system in which the valve timing (i.e., valve opening and closing) remains unchanged.
-
09/16/2020
How to save electricity for air compressor inverter controller
The phenomenon of "big horse-drawn carts" of air compressors is very common. It has two reasons: First, in the selection stage, the air compressors selected by the engineers are often higher than the maximum demand of the drive load.
-
04/07/2023
Which Brand of Refrigerator is Better (6 Top Refrigerator Brands 2023)
We have already introduced the types of compressors commonly used in refrigerators. Here, let's take a look at the world-famous refrigerator brands.
-
08/16/2020
What should I do if the screw of the rod-type chiller bites to death
Screw chillers are widely used in industry and chemical industry. Screw chiller is just one type of screw refrigeration series. There are also medium and low temperature screw chillers, air-cooled screw chillers,
-
06/14/2020
Analysis of the current status of refrigeration compressor technology development
Analysis of the current status of refrigeration compressor technology development
-
03/13/2021
Working mode of servo driver
The working modes of servo driver are: open loop mode, voltage mode, current mode (torque mode), IR compensation mode, Hall speed mode, encoder speed mode, tachometer mode, and analog position loop mode (ANP mode). (not all of the above modes exist in all models of drives)
-
07/18/2020
The safe operation rules of the cold storage Freon refrigeration compressor unit
Safety operating rules for Freon refrigeration compressor units in cold storage Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them.