Series | RS Series |
Type | Rotary Compressor |
Refrigerant | R22 |
Phase | 1PH |
Volt | 220-240V |
Hz | 50Hz |
Mitsubishi Compressor RS218VBAC
People who bought this item also viewed
Hitachi Compressor BSA645DT-R1EN
GMCC Compressor BG108X1C-20FZ
Hitachi Compressor ASL155SN-C7EU
Toshiba Compressor KSK103D33UEZ3
Mitsubishi Compressor JH521TEB
Mitsubishi Compressor BE96YEKMT
Mitsubishi Compressor NN31YCAMT
Mitsubishi Compressor RB174YNLC
Danfoss Compressor MLZ015T4LP9
Carrier Compressor 06DA8252BC0600
GMCC Compressor ASM140V1VFT
Bristol Compressor H29B28UDBV
Schneider Transformer ABL6TS04G
Siemens Contactor 3RT2016-1AF01
Delta Fan DFB0912H
XD Electric Motor XD2IK06GN-C
MAHLE Filter LX4786
EMERSON Sight Glass AMI-1MM4
ELNA Capacitor 50V 15UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
JSCC Reduction Drive 90YB120DV22
GESTRA Level Meter NRG19-50 L=500
Sanyo Compressor C-5R433H8C
AirTAC Air Cylinder SGC125X75
Recent related posts
-
06/13/2020
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass"
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass" The energy regulation of the system is generally composed of the following ways: Compressor parallel-multi-stage contro 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ
-
06/22/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
08/15/2020
What should I do if wall cracks appear after the cold storage is built
After the construction of the cold storage project, there may be many problems. For example, we have seen a lot of news recently. It is said that the wall cracks appeared after the construction of the cold storage
-
01/03/2021
The knowledge about the intake valve of the screw air compressor is here
The air compressor intake valve can also be said to be an intake control combination valve, which has functions such as intake control, loading and unloading control, capacity adjustment control,
-
06/13/2020
Brief introduction Principle and advantages and disadvantages of refrigeration piston compressor
Brief introduction Principle and advantages and disadvantages of refrigeration piston compressor Principle: Rely on the reciprocating motion of the piston to compress the gas in the cylinder. Usually through the crank connecting rod mechanism, the rotary 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ
-
03/01/2022
Factors Affecting Air Compressor Performance in Long-Period Operation
Through the research on the use and periodic failure factors of compressors in recent years, it is known that bearing clearance.
-
08/03/2020
Can the central air conditioner be installed after the renovation It's still a reliable teacher and solved it immediately
Although the decoration steps are just those, I always feel that there is no problem as long as the construction is carried out according to the steps, but there are always some annoying things in the middle.
-
03/20/2024
DC Servo Motor: Working Principle, Pros &Cons, Speed Adjustment Methods and Application
DC servo motor is a high-precision, high-speed, high-reliability motor that is widely used in various industrial fields. It controls the motor speed and position through a closed-loop control system, which can achieve extremely high motion control accuracy.
-
11/08/2023
Centrifugal Fan vs. Axial Fan: Understanding the Differences and Applications
Centrifugal fans and axial fans are two common types of fan systems used in various industries and applications.
-
07/05/2020
Hitachi 101 cold storage compressor
Hitachi 101 cold storage compressor The role of the compressor in the air conditioning system From the current development trend of refrigeration compressors, in order to make it compact, efficient, energy-saving and low-vibration and low-noise, it has become the goal that air-conditioning compressors continue to pursue in manufacturing technology.