Rechi Compressor 50R4732
Disp. (cc/rev) 32.5
Capacitor (μF) 35
Capacitor (VAC)370
Cooling (Btu/h) 18350
Capacity (W)5375
Input Power (W)1745
EER (Btu/h.W) 10.52
COP (W/W) 3.08
Testing Condition ASHRAE/T
Rechi Compressor 50R4732
People who bought this item also viewed
Mitsubishi Compressor RHV135FCC
Rechi Compressor 48R473A
Rechi Compressor 44R273A
Rechi Compressor 39E073B
Rechi Compressor 44R193A
Sanyo Compressor C-R223L8C
Bristol Compressor H79B24UABH
Hitachi Compressor K503DH-80D2
Copeland Compressor ZP54K3E-TFD-522
Tamura Transformer 3FD-436
Emerson Alco Expansion Valve TCLE-3HCA
Siemens Contactor 3RT1054-1AV36
Sanyo Denki Fan 109P0424F601
PARKER Filter G04195
EMERSON Sight Glass HMI-1MM4
SCHNEIDER Capacitor BLRCH400A480B52
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SANREX IGBT Module DF100LA80
SICK Light Curtain SPL-F280PPS1W04
KOGANEI Solenoid Valve 243-4E2-C-PLL
MALLORY Capacitor CGS 450V 380UF
Recent related posts
-
07/06/2020
Air Compressor Market product type, technology, lubrication, application, key Players and region Analysis
The dramatic spread of COVID-19 has created a marginal impact on the global air compressor market. The sustainability of the air compressor market is mainly attributed to the significantly increasing demand from various industries such as oil & gas, healthcare, chemical manufacturing, and many others. In addition, it is expected that the demand for the air compressor will be ultimately restored after the outbreak of COVID-19.
-
09/21/2020
Application of synthetic lubricating oil in processing and hydrocarbon gas presses
1. Hydrocarbon and process gas compressor lubricants Historically, hydrocarbon, chemical processing and inert industrial gas compressors have used traditional mineral oil-based lubricants. However, mineral oil cannot meet the needs of many modern rotary compressor designs and other complex applications. A typical gas processing application is at an outflow temperature of 80-1100C and a pressure of 7-70barg.
-
05/22/2023
Why is My AC Not Cooling? (Detailed Reasons and Solutions)
The air conditioner is a household appliance that we mostly use in the summer, and occasionally we encounter the problem of the air conditioner not cooling.
-
09/09/2020
What are the problems of traditional air compressors compared with frequency conversion air compressors
Variable-frequency air compressors have certain advantages in many aspects, so what are the problems of traditional air compressors compared to variable-frequency air compressors? Today I will tell you about the problems of traditional air compressors.
-
06/14/2020
The Secret of Counterfeit Refrigeration Compressor watermark
The Secret of Counterfeit Refrigeration Compressor Mass consumer goods, especially branded products, once counterfeit, copycats, etc., there will be a large number of media and professional counterfeit ears to remind consumers. However
-
08/19/2020
Why do industrial chillers need to replace high-quality antifreeze regularly
When the industrial chiller is running, there are high requirements for the use of antifreeze. Ordinary equipment cannot use high concentration antifreeze. If the concentration of antifreeze is high, it takes a long time to warm up before operating the equipment.
-
07/11/2020
Screw compressor principle and structure
Screw compressor principle and structure content Screw compressor characteristics Screw compression principle DXS compressor structure Application of DXS compressor in YCWS unit Screw compressor characteristics
-
11/18/2021
Rosemount Transmitter Series 1151, 2088, 2051, 3051CA, 3051S and the Differences
Rosemount pressure transmitter is a kind of general pressure transmitter. It is manufactured according to the law of electromagnetic induction and JB/T9248-1999 standard.
-
06/14/2020
Fully enclosed piston compressor
Fully enclosed piston compressor
-
06/24/2020
What is the solution of air conditioning not cooling
There are many reasons why the air conditioner is not cooling. For example, if the air conditioner refrigerant is insufficient, you can find a professional to add snow; secondly, it may be caused by the error of the air conditioner installation, such as the ventilation pipe is too long. It is recommended to shorten the length of the ventilation pipe; A lot of dust stains accumulate on the radiator and cause no cooling. It is recommended to clean the air conditioner.