Lutron Conductivity Meter YK2005CD
Type: Conductivity Meter
Brand: Lutron
Type: Conductivity Meter
Brand: Lutron
Type: Conductivity Meter
Brand: Lutron
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Hitachi Compressor WHP01900BUV-H6JUW
OMRON Power Supply S8VM-15024P
SYNCHROFLEX Belt T 5-575
Autonics Rotary Encoder E50S8-150-3-V-24
09/14/2020
SOLEST series synthetic refrigerating oil: SOLEST LT-32, SOLEST 46, SOLETS 68, SOLEST 120, SOLEST 170, SOLEST 220, SOLEST 370, CP-2931AH, CP-2931A Refrigeration oil: CP-1008-68, CP-1009-68, CP-1516-100, CP-1516-150, CP-4600-68, CP-4600-100, CP-4700-32, CP-4700-68 , CP-4700-100
12/16/2023
Having a properly functioning HVAC system is essential for maintaining a comfortable and controlled indoor environment.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
04/03/2023
The so-called compressor is a kind of machinery that compresses low-pressure gas to high-pressure gas, and it provides power for refrigeration cycles, gas transportation or pneumatic tools, etc.
04/20/2023
Refrigerator plays an important role in our life, and it helps us keep food fresh, such as fruits, milk, eggs, vegetables, meat and so on.
12/07/2022
For the sake of better performance, smaller wear, and longer service life of the linear guideway, proper lubrication is entailed. This article will discuss the functions, characteristics of lubricant and tips for lubrication.
06/25/2020
1.The air conditioner remote control may not adjust the temperature. 2. It may be that the air conditioner has not been cleaned for too long, which causes dust to accumulate on the filter net, so that the cold air blocking the air conditioner cannot be blown out. 3. There may be leakage of freon in the air conditioner, resulting in too little freon, and the air conditioner is not cooled. 4. Energy saving is due to unstable voltage, which causes the air conditioner to not be cooled. 5. It may be that the number of air conditioners is insufficient, and the small number of horses is not used for cooling in a large area of the house.
07/07/2020
The aging of air conditioners caused fires. The heat is coming. Are your home appliances overaged? The police reminded: As summer is approaching, we should pay attention to the service life, quality and installation environment of household appliances. The wires of many electrical appliances are mainly insulated by a layer of rubber on the outside.
07/04/2020
COVID-19 (Coronavirus) has resulted in many advantages and disadvantages for companies in the Oil Free Compressor market. Research report of this Oil Free Compressor market is highlights key strategies that can help reduce the impact of COVID-19 on diverse business practices.
12/05/2020
Air compressor dew point meter-suitable for compressed air and compressor post-processing drying equipment dew point meter, Michell products include a variety of online dew point meter and portable dew point meter, as well as dew point meter analysis system, fast response speed and good reliability.