There is no price at present, you can Request a Quote
Series | ECM-B3 Series |
Product | AC Servo Motor |
Type | Low Inertia |
Rated Voltage | 220 V |
Rated Speed | 3000 rpm |
Encoder Type | Incremental magnetic encoder |
Encoder Resolution | 17-bit |
Motor Frame Size | 40mm |
Output | 100W |
Brake | With Brake |
With Oil Seal | Yes |
Shaft Type | Round Shaft |
Shaft Size | Standard Shaft Diameter |
Delta Servo Motor ECM-B3L-CM0401DJ1
There is no price at present, you can Request a Quote
People who bought this item also viewed
Panasonic Servo Motor MSMD042P1U
Delta Servo Motor ECMA-C20604PS
Delta Servo Motor ECMA-C20604RS
Delta Servo Motor ECMA-C10602ES
Delta Servo Motor ECMA-C21010FS
Schneider Servo Motor BCH1304N12F1C
Mitsubishi Servo Motor HC-RFS203B
Yaskawa Servo Motor SGMGH-20ACA6B
Sanyo Denki Servo Motor P20B13300FXSH1E
Panasonic Servo Drive MADHT1105BA1
EMG Servo Valve SV 1-10/8/315/6
Siemens HMI 6AV3 627-1QL00-0AX0
BOURNS Encoder ENT1D-D28-L00100L
Puls Power Supply SLR2.100
Fuji PLC NP4N-TSPSV2
Newstart Speed Reducer PS190L2-15-P2-S2
MITSUBISHI Spindle Amplifier MDS-C1-SPH-150
HONGFA Relay HF175F-6-2HTF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Autonics Rotary Encoder E40S8-512-3-V-24
Ebmpapst Fan RER175-39
Rockwell A-B Sensor 873E-EDZZ0750A2
PHOENIX Relay 2966184
STNC Air Cylinder MGPM12-50
Mitsubishi Servo Motor HA-FH13
Recent related posts
-
08/29/2020
Discussion on ways to reduce the design cost of air compressor
Reduce the friction between the end face of the crankshaft and the end face of the crankcase On the direct-coupled air compressor, the front end of the crankshaft adopts gear transmission, and the gears are divided into straight and helical teeth.
-
06/13/2020
Working principle of York screw compressor
Working principle of York screw compressor Working principle of York screw compressor, screw compressor is a volumetric compression machine with working volume for rotary motion. The compression of gas depends on the change in volume, and the change in v 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ
-
08/05/2020
Why does the refrigeration compressor produce overheat protection What matters should be paid attention to in the use of overload protector
The working principle and classification of the overload protector. The overload protector of the compressor for air conditioning generally adopts a snap-type bimetallic protector, which consists of a heating wire,
-
04/30/2023
What are Refrigeration and Air-Conditioning Compressor Heaters Used For
The compressor heater (oil heater, crankcase heater, compressor heating belt) is a part of the refrigeration compressor.
-
09/18/2020
List of foreign medium and high pressure compressors in the Chinese market
When it comes to high-pressure compressors, they are not commonly used air compressors. They are widely used in pressure testing, chemical, bottle blowing, engineering, energy, electric power, military, medical and other industries. The general batch is relatively small, and domestic I think the high-pressure machine market is still in a budding state, and there is no more good capital and technical force to invest in this aspect of production;
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/22/2020
Compressed air purification equipment
Compressed air is the most important energy source in modern industry, but clean compressed air can show its advantages. Okmarts.com can provide you with a complete set of equipment from compressors to compressed air purification equipment.
-
05/13/2022
What Are The Input And Output Module (I / O) of PLC?
PLC I/O is the part of the PLC that connects the brain of the PLC, the CPU, to the outside world, the machines.
-
10/22/2021
List of Problems and Solutions for Centrifugal Air Compressor
As a speed type air compressor, centrifugal compressor can generate air flow moving in radial direction.
-
07/28/2020
Air-conditioning animation, wind system and water system can be understood at a glance!
Air-conditioning animation, wind system and water system can be understood at a glance! First, let's take a few professional and traditional central air conditioning systems 1.Water cooling unit +AHU/FCU