EALY Vane Pump 50T-07-FRL-PB-10
People who bought this item also viewed
EALY Vane Pump VPE-F20B-10
EALY Vane Pump VPE-F15B-10
EALY Vane Pump VDC-1A-F20D-20
EALY Vane Pump 50T-39-FRR-X-10
Yuci Vane Pump PFE-41045-1DT
KEISTER Vane Pump SQP2-25-86S-1B
Camel Vane Pump VCM-SF-12B-20
Yuci Vane Pump PFED-32022-016-1DT
SMC Proportional Valve ITV2050-33F3BN2
KOMPASS Check Valve CIT-03-A2
Jeou Gang Overflow Valve DB-G10-E2
Boden Gear Pump BHP2A0D22C1L3
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TTO Oil Seal TC 95*110*12
ADDA Fan AD0412LB-C56
CKD Air Cylinder GRC-20-180-A1
AirTAC Air Cylinder SCJ200X200-50
HOSSONI VFD Frequency Converter HB-S9-037T3
KCL Vane Pump DVQ20-17-F-RAA-03
BANDO Belt H-1100-381
PARKER Filter FBO60341
Recent related posts
-
09/08/2020
The evolution history of air compressors
The (mechanical) vacuum pump made in Germany in 1640 is the originator of modern air compressors. Around 1800, the first single-stage (reciprocating piston) air compressor was made in the UK, and its discharge pressure was 1.38MPa (gauge pressure).
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/21/2020
Calculation and determination of gas consumption
The traditional method of determining the compressed air requirements of a new plant is to add up the air consumption (m3/min) of all air-consuming equipment, and then consider adding a safety, leakage and development factor
-
09/09/2020
Industrial bearing knowledge
Structural features Bearing seat: The bearing seat is made of cast iron with heat sink on the surface. The mating surface of the bearing seat and the bearing bush is spherical. Bearing seats are divided into two types: insulated and non-insulated.
-
06/14/2020
Don't panic if the refrigeration compressor suddenly stops, remember these methods!
What should be paid attention to when the refrigeration compressor stops abnormally? Some friends may not understand it. Let's take a look at it with everyone today!
-
05/21/2022
How to Select A Air Cylinder?
There are various of air cylinders and it is very important to choose the appropriate model. We provide you with the process of air cylinder selection as follow.
-
07/02/2020
Danfoss US Youle MANEUROP compressor MTZ-28 latest offer wholesale parameters performance introduction
Danfoss US Youle MANEUROP compressor MTZ-28 latest offer wholesale parameters performance introduction Danfoss US Youle MANEUROP compressor MTZ-28 offer wholesale parameters, distributor Technical parameters of Meiyou compressor:
-
01/04/2021
Compression Ratio, Capacity and Volumetric Efficiency of the Refrigeration Compressor
Compression Ratio, Capacity and Volumetric Efficiency of the Refrigeration Compressor Piston Displacement, Compressor Capacity, Clearance Volume of Compressor Introduction This article describes some important terms related to the refrigeration and air 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵
-
07/30/2020
Reason analysis of refrigeration compressor can not start or stop soon after start
First check the main circuit. Whether the power supply has electricity, whether the voltage is normal, whether the fuse has been blown due to starting overload, whether the air switch has tripped,
-
07/18/2020
The advantages and disadvantages of screw refrigeration compressor
Power compressor is indispensable when refrigeration equipment is cooling. Such as chillers, chromatography freezers, ice machines, ultra-low temperature refrigerators, etc., their driving force is the refrigeration compressor, the entire refrigerant cycle is the refrigeration compressor