There is no price at present, you can Request a Quote
Input voltage:240V
Input current:12A
Input frequency:50/60Hz
Input Phase:1
Output voltage:240V
Output current:6.5A
Output Phase:3
Output frequency:0-900Hz
Emerson Servo Drive EP206-I00-EN00
There is no price at present, you can Request a Quote
People who bought this item also viewed
Delta Servo Drive ASD-A2-3023-F
Allen Bradley Servo Drive 1398-PDM-050
Mitsubishi Servo Drive MR-J2S-22KA
Mitsubishi Servo Drive MR-J3-10B-PE053
Moog Servo Valve 631-102c
Delta HMI DOP-B07E411
HENGSTLER Encoder RI58-O/100EQ.46KB
SIEMENS Actuator GEB164.1E
Delta PLC Host DVP40EH00T3
JSCC Reduction Drive 90YB60DY38
MITSUBISHI Spindle Amplifier MDS-B-V1-20
Omron Input Output Module E53-CZHB
TYCO Relay PRDA-11DYA-12
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CKD Air Cylinder SCA2-CB-40B-200
Ebmpapst Fan 4656Z
INA Linear Guideway KUVE45-B-HL
SHAKO Air Cylinder JC50B25-H-M
AirTac Solenoid Valve B03-4V310-AC220V
Recent related posts
-
02/15/2023
Installation and Maintenance of Gearbox
When you select gearbox model, four factors should be given comprehensive consideration.
-
07/03/2020
Mute Oil Free Air Compressor Market Report 2020-2026 | Competitor Analysis | Atlas Copco (Sweden), Ingersoll Rand (Ireland), Sullair (USA)
Piston Compressor Market Size 2020 Global Industry Trends, Share, Growth, Applications, Demand, Revenue, Key Players, Opportunities, Regional Analysis and Forecast 2026 This latest market research study titled Global Piston Compressor Market 2020 landscape and leading manufacturers offers competitive outlook and market development status including the overview of every individual market players.
-
08/11/2020
Selection of cold storage electrical control system and other design considerations
Selection of cold storage electrical control system and other design considerations<br></br> The refrigeration electrical control system is a necessary condition to ensure that the cold storage always automatically works within the set range. Its main work flow includes:
-
12/06/2022
How to Maintain a Linear Guideway?
Linear guideways are precision transmissions and require careful maintenance in order to give full play to their functions and prolong their service life. The followings are tips for the maintenance of the liner guideway
-
08/05/2020
How to solve the problem of too high compression ratio of chiller
In the process of using industrial chillers, various problems will inevitably occur. Due to the structure of the industrial chiller, once the compression ratio of the compressor is too high, it will affect the working efficiency of the industrial chiller.
-
03/01/2021
Advantages and disadvantages, function and service life of brushless motor
Advantage: (1) No brush, low interference When the brush is removed from the brushless motor, the most direct change is that there is no electric spark generated when the brushless motor is running, which greatly reduces the interference of electric spark to the remote control radio equipment.
-
12/16/2022
How to Fix a Damaged Memory Card?
Memory cards are very convenient for data storage and transfer. What should we do if we find that our memory cards are damaged
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/11/2020
Matters needing attention in improving the quality of cold storage installation
In fact, different construction methods and installation materials are the key to directly affecting the smooth progress of the cold storage installation project.
-
06/29/2020
Precautions for the use of screw air compressor oil
Precautions for the use of screw air compressor oil Note on the use of screw air compressor oil: It is forbidden to mix air compressor oils of different brands and grades. The old oil must be drained when replacing. It is strictly forbidden to add or filter and reuse.