Output Voltage("H"):[(Supply Voltage) -2.5 V] or more
Output Voltage("L"):0.4 V or lower
Output Current(Source "H"):Up to 10 mA
Output Current(Sink "L"):Up to 30 Ma
KOYO Solid-shaft Incremental Rotary Encoder TRD-N600-SW
People who bought this item also viewed
Autonics Rotary Encoder E40H8-512-3-N-24
Autonics Rotary Encoder EP50S8-64-2F-N-5
HENGSTLER Encoder S21-2048.003
Lika Encoder IT65-H-1024ZCP4ER
Mitsubishi Servo Motor HA-LFS22K24B
Inovance Servo Drive IS620PS7R6I
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Eaton Moeller Circuit Breaker NZMS1-S50
STAIRS Water Pump CBK12-60/5
PANASONIC Capacitor 16V 3900UF
Festo Air Cylinder DGC-18-250-GF-PPV-A
Recent related posts
-
08/20/2020
The reason why the compressor of industrial chiller cannot start
What is the reason why the industrial chiller cannot be started? The compressor is the core part of the industrial chiller. If it cannot be started, the entire unit cannot operate normally. When the compressor is started,
-
08/02/2020
Analysis of common problems of slow cooling and heating speed of air conditioning
Recently, many people have asked why the cold storage project has a rapid constant temperature after a power failure. This problem is believed to occur when many users use the cold storage.
-
09/08/2020
Air compressor lubricant model the difference between No. 32 and No. 46 air compressor lubricants
Air compressor lubricants are generally No. 32 oil and No. 46 oil. No. 32 is a mineral type. The general service life is about 2000 hours and needs to be replaced. The operating temperature must be below 90 degrees to avoid carbon deposits.
-
09/08/2022
Permanent Magnet DC Motor: Types, Application, Selection Principle (1)
A <strong>permanent magnet DC motor</strong> (PMDC motor) is a type of DC motor that uses permanent magnets to create a magnetic field.
-
03/10/2021
The main circuit fuse fusing is a common fault of SCR servo driver. The causes of fuse fusing are as follows
The "phase sequence" of power incoming line is incorrect. Due to the synchronization problem between the trigger pulse and the main circuit of SCR servo driver, there are strict requirements on the "phase sequence" of the input power supply. If the "phase sequence" is not correct, connecting the power supply may immediately cause the fuse of the main circuit of the driver to blow.
-
06/28/2020
Trouble analysis and elimination of semi-hermetic compressor motor
Trouble analysis and elimination of semi-hermetic compressor motor Abstract:Semi—hermetic compressor often be used in the water—cooling unit of air conditioning system,and it’S motor which work in rather high temperature and pressure condition,even work with refrigerator and oil, has a poor working condition.
-
06/13/2020
Compared with the air conditioner in the living room and bedroom, the kitchen air conditioner has no essential difference in the compressor
Small refrigeration equipment drives compressor growth It is understood that the main difference between the kitchen air conditioner and the conventional living room and bedroom air conditioner is the design of the indoor unit. There is no essential diff ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ 뤂ᐱ變뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់變ᩄ ꋔྦ 瑉浥 巠皱㙲皦
-
12/16/2021
How to Reduce Noise of Air Compressor?
Air compressors can provide stable air flow with little pressure fluctuation, which has the advantages of stable rotation and high efficiency.
-
12/27/2022
Classifications of Programmable Logic Controller
The programmable logic controller (PLC) is a digital operation controller with microprocessor for automatic control, which can load control instructions into memory for storage and execution at any time.
-
12/19/2022
What is an Optical Fiber Amplifier?
The optical fiber amplifier, also known as the optical fiber ampler (OFA for short), refers to a new type of all-optical amplifier used in optical communication link to realize signal amplification.