Resolution: 400P/R
Output Signal: A, NOT A, B, NOT B, Z, NOT Z
Output Curcuit: Line Driver DC+5V-28V
Current Consumption: 150mA Max.
Response Frequency: 200kHz Max.
Rise and Falling Time: 0.2 microseconds
Maximum Rotation Speed: 6000 RPM
Vibration Resistance: 10-55Hz / 1.5mm
Shock Resistance: 50G / 11msec
Protection: IP50
Cable Length: 100cm
Operating Temperature Range: -10 degrees-+70 degrees
Storage Temperature Range: -20 degrees-+80 degrees
Kwangwoo KW Encoder RIB-40-0400VL
People who bought this item also viewed
Autonics Rotary Encoder E40H8-1000-3-N-5
Renishaw Encoder RGH24Y50F33A
Nemicon Encoder AEW2-8-GC-H6-050-00E
SIEMENS Servo Motor 1FK7033-7AF21-1LB0
Fanuc Servo Drive A06B-6092-H275
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TECO Water Pump TSM0R525
MALLORY Capacitor 63V 320000UF
ORION Fan OA254AP-11-1TBSF
Beckhoff Slave Card Module FC1121
Recent related posts
-
10/16/2020
What is the cause of insufficient displacement of Copeland compressor
Insufficient compressor displacement has a great impact on the entire refrigeration system. If it is not repaired and handled in time, it may cause problems such as the cylinder, cylinder head rupture, and compressor water intake, which will destroy the entire refrigeration system cycle. It may even cause accidents such as compressor combustion and explosion. So what causes the insufficient displacement of Copeland compressor? Let's take a look.
-
10/02/2023
Dryer Heat Pump vs Condenser: Which One Should You Choose?
When it comes to choosing a clothes dryer, there are a lot of options to consider. One of the most important decisions you'll make is whether to go with a dryer with a heat pump or a condenser. Both options have their pros and cons, so it's essential to understand the key differences between the two.
-
09/06/2020
What are the requirements of modern industry for oil-free air compressors
After the air is mechanically compressed, it becomes compressed air. The equipment used to produce compressed air is usually called an air compressor. Compressed air is an indispensable pneumatic energy source in people's production and life.
-
07/26/2020
How to select the thermal expansion valve?
1. The role and classification of expansion valves<br></br> Expansion valve is an important part of refrigeration system, generally installed between liquid storage cylinder and evaporator. The expansion valve causes the medium temperature and high pressure liquid refrigerant to become low temperature and low pressure wet vapor through its throttling, and then the refrigerant absorbs heat in the evaporator to achieve the cooling effect.
-
07/18/2020
The core heart of the chiller-compressor
Power compressor is indispensable when refrigeration equipment is cooling. Such as chillers, chromatography freezers, ice machines, ultra-low temperature refrigerators, etc., their driving force is the refrigeration compressor, the entire refrigerant cycle is the refrigeration compressor
-
06/14/2020
The reasons for the high temperature of the compressor discharge are
The reasons for the high temperature of the compressor discharge are (1) The clearance in the compressor cylinder is too large; (2) The suction and exhaust valves and piston ring of the compressor are damaged; (3) The compressor safety bypass valve 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥
-
11/23/2022
How to Fix an Air Conditioner Fan Motor?
The air conditioner is composed of heat and cold sources, wind system, water system, air conditioning treatment equipment, and devices for controlling and regulating air conditioning.
-
08/20/2020
Emergency shutdown treatment for sudden cooling water cut
During the operation of refrigeration equipment, accidents of sudden cooling water interruption sometimes occur. The cause of this accident is generally the failure of the cooling water pump.
-
09/05/2020
The role of air compressor air filter and the hazards of overdue use
The air compressor air filter (also known as style) is composed of an air filter assembly and a filter element. The outside is connected to the air compressor's intake valve through a joint and a threaded tube to filter the dust, particles and other impurities in the air.
-
07/17/2020
Reasonably adjust the cold storage evaporator and defrost in time
Reasonably adjust the cold storage evaporator and defrost in time Generally speaking, every increase in the cold storage evaporation temperature can save energy Therefore, under the premise of satisfying the low refrigeration process of the product, the evaporation temperature can be increased as much as possible by adjusting the amount of liquid supplied. The thermal resistance of the frost layer is generally much larger than the thermal resistance of the steel pipe.