Current Consumption: 50 mA Max
Resolution: 25P/R
Output Voltage:H +5v ,Add and subtract 10%
L 0.5V Max
Maximum Frequency Responese: 5kHz
Maximum Sink Current: 20 mA
Nemicon Encoder UFO-M2-0025-2H-B00E
People who bought this item also viewed
Nemicon Encoder NOC-H1024-2MC
Nemicon Encoder HP-V0025-2H-PL1-300-00E
Nemicon Encoder 7S-100-2MC-50-00E
Nemicon Encoder NE-1024-2MD-F-068-08E
HENGSTLER Encoder AC58/0015AS.41SGB
MTL Encoder MES-40-720P
Sanyo Denki Servo Motor T720-012EL0
Parker Servo Drive MPA-15-116A
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
COKERY Belt B112
ST IC Integrated Circuit E-L9758BBTR
Siemens HMI 6AV6 643-8AD10-0AA1
SHAKO Air Cylinder PCL32B175
Fotek Temperature Controller NT-48RE
INTERMOT Hydraulic Motor F68-6000
Recent related posts
-
03/02/2021
Control mode of servo motor
Torque control: the torque control mode is to set the external output torque of the motor shaft through the input of external analog quantity or the assignment of direct address. For example, if 10V corresponds to 5nm, when the external analog quantity is set to 5V, the output of the motor shaft is 2.5nm: if the load of the motor shaft is lower than 2.5nm, the motor will rotate forward, and when the external load is equal to 2.5nm
-
08/13/2020
How to apply the functions of cooling, heating, humidification, and dehumidification of computer room air conditioning
1. Uninterrupted operation and year-round refrigeration<br></br> The heat dissipation of the equipment in the computer room is a steady-state heat source, and it operates continuously throughout the year. This requires an uninterrupted air-conditioning gPﰨ2 䀀 湠癐
-
08/20/2020
Introduction of solenoid valve and troubleshooting method
1. Symptoms-the solenoid valve does not open possible reason: 1 The coil has no voltage. 2 Incorrect voltage/frequency 3 Coil burned out 4 Pressure
-
07/20/2020
Analysis of circuit diagrams of two compressors' phase failure protection
Analysis of circuit diagrams of two compressors' phase failure protection Air compressor phase failure protection circuit Protection circuit diagram Air compressor phase failure protection circuit
-
09/21/2020
Refrigeration system failure symptoms
Symptoms of refrigeration system failure 1. Detection of pressure and temperature of refrigeration system (1) The pressure concept of the refrigeration system The refrigeration system can be divided into high and low pressure during operation. The high pressure section is from the discharge port of the compressor to before the throttle valve. This section is called the evaporation pressure.
-
01/22/2023
How to Deal with Spindle Amplifier Alarm Codes?
When faults occur, there will be various alarm codes on the Spindle amplifier, each representing different faults.
-
06/21/2022
Classification and How Does a Transformer Work?
Transformers are electrical devices consisting of two or more coils of wire that are used to transfer electrical energy by means of a magnetic field.
-
01/24/2024
Industrial Control Cabinet Cooling: How to Design the Cooling and Ventilation System?
Control cabinets, such as wind turbine electrical control cabinets, realize system power distribution, monitoring and control of the entire unit.
-
07/15/2020
What you need to know about Copeland compressors
The operation of Copeland Scroll compressor is directional. It can only rotate in one direction for compression. The specific direction of rotation depends on the phase force. If the scroll compressor rotates in reverse, it will cause insufficient lubrication of the system and cause scroll wear or damage to the scroll components.
-
09/06/2022
How to Select Overflow Valve
The nominal pressure of the overflow valve is determined by the operating pressure, the service temperature range of the safety valve is determined by the operating temperature