There are four main components in the refrigeration system, namely compressor, condenser, throttling device (such as capillary tube, expansion valve), evaporator.
07/17/2023
If you work in the refrigeration or air conditioning industry, you know how important it is to keep your compressors properly lubricated.
06/14/2020
There is solar energy in the water vapor, which can be used for heating and cooling What is water vapor energy? This unfamiliar term is actually not difficult to understand
07/16/2020
1. The pressure of the scroll compressor is generated due to the interaction between the scroll disks that make planetary motion. When one of the scroll disks makes planetary motion, the gas enters from the outer opening.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
07/27/2020
Screw compressors, also called screw compressors, include screw air compressors and screw process compressors (vinyl chloride compressors, etc.).
06/14/2020
Advantages of natural gas used in air conditioning and refrigeration technology Natural gas-based refrigeration and air-conditioning technology has entered the market in developed countries in the middle of the last century.
08/15/2020
The cold storage is mainly used as a constant temperature storage air-conditioning equipment for food, dairy products, meat, aquatic products, etc. The cold storage is a kind of low-temperature cold storage and also a kind of refrigeration equipment.
08/07/2020
During the operation of the system, the lubricating oil is discharged from the compressor along with the refrigerant, and returns to the compressor after the cycle.
09/23/2020
1. Design intent For cost reasons, the control systems used in the air compressor manufacturing industry for a long time have been controlled by single-chip microcomputers, and digital tubes indicate working status and indicate parameter values