Stroke: 2 mm - 2000 mm
Piston diameter: 32 mm
Piston rod thread: M10x1.25
Type code: DNC
Cushioning: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Conforms to standard: ISO 15552
Piston rod end: External thread
Design: Profile barrel: Piston rod: Piston
Position sensing: For proximity sensor
Symbol: 00991235
Variants: Piston rod at one end
Operating pressure: 0.6 bar - 12 bar
Mode of operation: Double-acting
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
Corrosion resistance class (CRC): 2 - Moderate corrosion stress
Ambient temperature: -20 to 80 Celsius Degree
Impact energy in the end positions: 0.1 J
Cushioning length: 20 mm
Theoretical force at 6 bar, retracting: 415 N
Theoretical force at 6 bar, advancing: 483 N
Moving mass at 0 mm stroke: 162 g
Additional weight per 10 mm stroke: 30 g
Basic weight with 0 mm stroke: 517 g
Additional moving mass per 10 mm stroke: 9 g
Type of mounting: With accessories: With internal thread
Pneumatic connection: G1/8
Note on materials: RoHS-compliant
Cover material: Die-cast aluminum: Coated
Seals material: TPE-U(PU)
Piston rod material: High-alloy steel
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Festo Air Cylinder DNC-32-180-PPV-A
People who bought this item also viewed
KOGANEI Air Cylinder NHBRS-10
MINDMAN Air Cylinder MCRPLF-90-25-500
Compact Air Cylinder SD34X12
Festo Air Cylinder DNU-50-300-PPV-A
Festo Air Cylinder ADVU-50-25-A-P-A
Festo Air Cylinder ADN-32-25-I-P-A
AirTAC Air Cylinder HLH16X10S
Festo Air Cylinder DGSL-10-30-PA
Festo Air Cylinder DGC-12-330-G-P-A
HENGSTLER Encoder RI76TD/2048AD.1A38RF
Daikin Solenoid Valve LS-G02-2CC-30-EN
Belimo Actuator LM24A-T
Bellofram Proportional Valve 969-720-000
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
MALLORY Capacitor 360V 2500UF
KCM Industrial Chain KCM 40 SS-2
Recent related posts
-
07/01/2022
How to Install a Sump Pump Check Valve: 5 Steps
What is a sump pump check valve? It is a device that keeps water from reentering the discharge pipe whenever the pump is not running.
-
09/23/2020
Application of DCS system in anti-surge control system of air separation compressor
Keywords: DCS system, air separation compressor, anti-surge control system Preface The 6000m3/h air separation plant of Xilin Iron and Steel Company was completed in May 2001 by Hangzhou Oxygen Concentrator Group Company. The factory design was designed by Beijing Iron and Steel Design Institute. It was successfully put into operation on September 2, 2001, and it took more than half a year to run. It shows that the unit is operating stably, and all indicators have reached or exceeded the design value. The entire control system uses Honeywell’s TDC3000 and two GUS stations.
-
03/10/2022
Why are Your Refrigerating Machine and Compressor Making Abnormal Noises?
The operation sound of the refrigerating machine is unavoidable. The fan rotating, fan blade rubbing with the air would make the noise that is normal.
-
06/24/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
08/07/2020
Working principle of frequency converter
Inverters can be divided into voltage type and current type inverters.<br></br> Voltage type is an inverter that converts the DC of a voltage source to AC. The filtering of the DC loop is a current type that converts the DC of the current source to A
-
08/29/2022
How do Circuit Breakers Extinguish Electric Arc?
The arc is a free gas with high temperature and high conductivity, which not only has a great destructive effect on the contacts
-
04/10/2023
How to Quiet a Noisy Refrigerator (11 Ways)
Many families will encounter such a problem, that is, the refrigerator makes a "humming" harsh noise during use.
-
05/20/2022
5 Common Faults and Solutions of Air Cylinders?
Cause 1: The guide sleeve, rod seal ring or piston rod are worn. Solution 1: Replace it. Improve lubrication. Use guide rails.
-
06/14/2020
What are the advantages and disadvantages of central air conditioning?
1. It is better to use a central air conditioner ① Split machine and multi-connection Before chatting, first understand the two basic concepts of air conditioning, split machine and multi-line. The split machine is our common common air conditioner. 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ӂ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
08/11/2020
Common practice of oil return design in refrigeration system
When the condenser is installed higher than the compressor, a U-shaped bend is required at the intake pipe of the condenser to prevent oil from returning to the exhaust side of the compressor during shutdown and also help prevent liquid refrigerant from the condenser