Adjustable end position range/length: 12 mm
Piston diameter: 25 mm
Type code: SLT
Drive unit operating mode: Yoke
Cushioning: Elastic cushioning rings/pads at both ends
Mounting position: Any
Guide: Ball bearing cage guide
Design: Scotch yoke system
Position sensing: For proximity sensor
Symbol: 00991249
Operating pressure: 1 bar - 10 bar
Mode of operation: Double-acting
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
Corrosion resistance class (CRC): 0 - No corrosion stress
Ambient temperature: -20 to 60 Celsius Degree
Impact energy in the end positions: 0.5 J
Max. force Fy: 1160 N
Max. force Fz: 1160 N
Max. torque Mx: 18 Nm
Max. torque My: 18 Nm
Max. torque Mz: 11 Nm
Theoretical force at 6 bar, retracting: 495 N
Theoretical force at 6 bar, advancing: 590 N
Moving mass: 1516 g
Product weight: 3210 g
Alternative connections: See product drawing
Type of mounting: With through-hole
Pneumatic connection: G1/8
Note on materials: Free of copper and PTFE
Cover material: Wrought aluminum alloy
Seals material: HNBR
Housing material: Wrought aluminum alloy
Piston rod material: High-alloy stainless steel
Festo Air Cylinder SLT-25-100-P-A
People who bought this item also viewed
Festo Air Cylinder DNC-40-1000-PPV-A
CKD Air Cylinder SCPG2-M-00-10-30
Festo Air Cylinder ADVC-32-10-I-P-A
Festo Air Cylinder DNU-80-200-PPV-A
Festo Air Cylinder ADVU-50-10-P-A
Festo Air Cylinder DGSL-20-20-P1A
CKD Air Cylinder SCA2-LB-63B-150
MINDMAN Air Cylinder MCJA-12-12-30M
AirTAC Air Cylinder TCM16X40S
HENGSTLER Encoder RI58-D/5000AD.32RF
Honeywell Solenoid Valve VE4080B1016
SIEMENS Actuator GIB163.1E
SMC Proportional Valve ITV3051-31N3CL4
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Transformer Y55-0135
CHELIC Solenoid Valve SF5-Y-S8-L
JAMICON Fan JF1238B2UM-R
AirTAC Air Cylinder SILF160X500S
CHANTO Air Cylinder ASR50X250
Recent related posts
-
09/10/2020
The management method of the air compressor room of the Red Fifth Ring
1. Choose a wide and well-lit place to facilitate the space and lighting required for the operation, maintenance and repair of the air compressor.
-
08/03/2020
Five classification functions of cold storage installation cold storage function
The refrigerated distribution center is developed based on the two needs of the rationalization of refrigerated logistics and the development of the market.
-
08/14/2020
Four Steps to Refrigeration Compressor Maintenance
Summer is coming, and the long-standing air conditioner will come in handy again! In recent years, consumers have become more and more experienced in the use of air conditioners,
-
10/15/2021
Piston Compressor Basics - Structure, Working Principle, Advantages and Disadvantages
As both manufacturers and end customers know, in a refrigeration or air conditioning system, the compressor is the equipment core by continuously sucking back and exporting refrigerant
-
03/17/2023
Six Common Faults and Solutions of Water Pump
What you need to do first is to check the power supply: whether the joint is firmly connected, the switch contacts tightly, the fuse is blown, three-phase power supply is equal.
-
07/08/2020
This is the key method to solve the leakage problem of fan coil
The fan coil and fresh air system is a widely used air-conditioning method. Because of its flexible layout and the ability of each room to be adjusted independently, it is commonly used in hotels, hotels, office buildings, hospitals and other buildings. However, many problems are often caused by mistakes in construction and design, and the most common one is water leakage.
-
06/21/2020
Causes and judgement of centrifugal compressor surge
Causes and judgement of centrifugal compressor surge Causes of centrifugal compressor surge ①Flow<img src="{{media url="Causes_and_judgement_of_centrifugal_compressor_surge.jpg"}}" alt="" /> Each centrifugal compressor corresponds to a curve between outlet pressure P and flow rate Q at different speeds n, as shown in Figure 2.
-
01/03/2021
Danfoss Thermostats
Cold Controls (thermostats) are subject to the LVD directives, meaning they must be tested according to this Directive so that customers can feel safe and secure during buying and installing these Cold Controls. Danfoss Cold Controls also called 077B to h 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧բ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
07/14/2020
Talk about explosion of air conditioner and refrigerant
As a household appliance, air conditioners are gradually going to thousands of households. Air conditioners have a history of hundreds of years, so we not only have to ask whether the early production of air conditioners has not exploded? Why the explosion of air conditioners happened in recent years has a close relationship with the refrigerants used in air conditioner production.
-
09/16/2020
Application skills of air compressor using oil and gas separator
Abstract: The application technical requirements of the oil-gas separation core used in air compressors, and the problems that occur during the use of the oil-gas separation core are analyzed, and the matters to be noted before installation.