FITIPOWER IC Integrated Circuit Chip FR8204S6CTR
- Specifications
- Q&A
- Reviews
LG LS PLC Power module GM6-PAFC
IXYS Rectifier Module VUO122-12NO7
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Schneider Sensor XS1N18PC410P
05/04/2023
Vapour compression refrigeration system (VCRS) is the most common cooling system used in modern refrigeration technology.
06/21/2020
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high Compressor suction pressure is too high, discharge pressure is too high 1. Too much refrigerant. Too much refrigerant will cause the suction pressure and discharge pressure to be too high at the same time. This is because when too much refrigerant fills the reservoir, it will occupy a part of the condenser volume, reducing the heat dissipation area and causing the condenser Poor condensation. Discharge excess refrigerant from the low-pressure side.
06/14/2020
The Secret of Counterfeit Refrigeration Compressor Mass consumer goods, especially branded products, once counterfeit, copycats, etc., there will be a large number of media and professional counterfeit ears to remind consumers. However
06/30/2020
What happens if the refrigerant recovery time of the air-conditioning compressor is too long At ordinary times, we will need to simply disassemble and assemble the compressor due to certain circumstances. However, if you do not pay attention to certain matters when disassembling, it will cause the compressor to be directly damaged, so you will not be able to compensate for it.
02/03/2023
Gear reducers are generally used for transmission equipment with low speed and high torque. The ratio of the numbers of teeth of the big and small gears equals the transmission ratio.
07/27/2020
The refrigeration compressor of the high and low temperature test chamber adopts the original French Tecumseh compressor. Its working principle is to suck in low temperature and low pressure refrigerant gas from the suction pipe, drive the piston to compress it through the operation of the motor
07/28/2020
Low voltage overrun protection:<br></br> Solution: Replace or clean the filter element; clean the suction port filter.<br></br> Dirty or ice blockage at the inlet of the expansion valve:<br></br> Solution: Dirty blockage: remove the expansion valve and clean it. Ice blockage: replace the filter drier and run again
08/17/2020
The relevant temperature of the components of the refrigeration and air-conditioning system has a normal temperature range, and it is an abnormal state if it exceeds this range.
08/20/2020
Multi-connection is commonly known as "one-to-many". A multi-connection system is an outdoor unit connected to multiple indoor units, and each indoor unit can be freely run/stopped, or grouped, or centralized.
06/14/2020
Advantages of natural gas used in air conditioning and refrigeration technology Natural gas-based refrigeration and air-conditioning technology has entered the market in developed countries in the middle of the last century.