Kromschroder Flame Detector IFW15-T
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
COMAT RELECO Relay C7-T21/AC48V
MITSUBOSHI Belt S3M-273-10
Recent related posts
-
06/29/2020
Precautions for the use of screw air compressor oil
Precautions for the use of screw air compressor oil Note on the use of screw air compressor oil: It is forbidden to mix air compressor oils of different brands and grades. The old oil must be drained when replacing. It is strictly forbidden to add or filter and reuse.
-
06/13/2020
What should I do if the refrigeration compressor has serious frost
1. The frost on the compressor return air port indicates that the temperature of the compressor return air is too low, so what will cause the compressor return air temperature to be too low?
-
06/24/2020
What's wrong with the freezer not cooling
There are four main reasons: the first is the lack of refrigerant and the compressor has problems; the second is the problem of the power cord of the freezer; the third is the frost in the evaporator of the freezer; the fourth is that the storage in the freezer is too full. Of course, no matter what the reason is, you should find a professional to help repair the loophole or add refrigerant.
-
04/25/2022
How to Install A Surge Protection Device?
Set power line surge protection device at the entrance of the line into the building, the interface of the lightning protection area and the place close to the protected equipment.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/30/2020
Broken suction valve of Bristol compressor
Broken suction valve of Bristol compressor A Bristol compressor is a machine that compresses gas. Generally, the piston compresses gas 1450 times per minute (half-sealed compressor) or 2900 times (full-sealed compressor), that is, the time to complete an intake or exhaust process is 0.02 seconds or even shorter.
-
08/08/2020
The cold water (freezing) machine displays the reverse phase loss fault quick troubleshooting
The cold water (freezing) machine shows a reverse phase loss fault, which is a common fault of abnormal power supply. The reason for this failure is simple, and it is very convenient to repair, as long as there is a little electrician foundation, it can bﰨ2 䀀 湠疖
-
08/09/2020
DORIN compressor
DORIN Compressor Co., Ltd. of Italy was established in 1918. It is one of the founding organizations of ASERCOM in Europe and one of the few top refrigeration compressor manufacturers in the world.
-
09/18/2020
Performance comparison between piston compressor and screw compressor
The noise of the piston engine is loud and the maintenance is inconvenient. Most piston machines often have problems during use, which brings great inconvenience to users. At the same time, it can reduce the production cost of the factory, increase economic benefits, facilitate equipment management
-
07/03/2020
PORTABLE AIR COMPRESSOR MARKET SWOT ANALYSIS BY GROWTH AND FORECAST FROM 2020-2026|STANLEY BLACK&DECKER,POWERMATE,CAMPBELL HAUSFELD,SENCO
DataIntelo report titled Global Centrifugal Air Compressor Market provides detailed information and overview about the key influential factors required to make well informed business decision. This is a latest report, covering the current COVID-19 impact on the market.