There is no price at present, you can Request a Quote
1 1/2" (40A), ø44 to ø55
2" (50A), ø55 to ø64
Supported pipeline materials:Metal pipe, resin pipe *1
Supported fluid:All liquids (water, oil, medicine, etc.) *1
Supported fluid temperature:-20 to +120 °C (no freezing on the surface of the pipeline) *2
Rated flow rate range: 5.0 m/s
Flow rate conversion value:
1 1/2" (40A): 400 L/min, 24 m 3 /h
2" (50A): 600 L/min, 36 m 3 /h
Zero cut: 0.3 m/s (default) *3
Flow rate conversion value: 36 L/min, 2.4 m 3 /h
Display method:2-segment 5-digit display using white 14-segment LED, large status indicator, output indicator, stability indicator, unit indicator
Display refresh cycle:About 3 times/sec
display resolution:0.1/1 (L/min)
Response time:0.5 s/1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)
measurement accuracy:From 20 to 100% of FS: ±2.0% of RD *4 *5 From
6 to 20% of FS: ±0.4% of FS *4 *5
protect the circuit:Power reverse connection protection, power surge protection, short circuit protection for each output, surge protection for each output
Zero error:±0.5% of FS *4 *6
Hysteresis:variable
Flow unit:L/min, m 3 /h
Integrated flow device display:1/10/100/1000/10000 (L)
Piping temperature detection accuracy:±3 °C (piping temperature -20 °C to +50 °C), ±5 °C (piping temperature 50 °C to 120 °C)(at 25 °C ambient temperature) *4
Body unit size: 218.5 mm x 66.9 mm x 70.7 mm
weight:Main unit: about 1.0 kg
top/bottom bracket: about 1.5 kg (including separation unit)
KEYENCE Flowmeter FD-R50
There is no price at present, you can Request a Quote
People who bought this item also viewed
YOKOGAWA Flowmeter AXFC-4-L010/CH
Gems Level Meter XT-36490
Eutech Turbidity Meter ET99729
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Yuci Vane Pump PFED-43037-036-1DT
Rockwell A-B Sensor 42EF-P2MPB-F4
PARKER Switch SCP01-600-24-06
JIE&MING Overflow Valve YF-B10K-Y1
COSMO Relay D1A241000
Recent related posts
-
06/20/2020
Working principle of reciprocating compressor_Working process of reciprocating compressor
Working principle of reciprocating compressor<img src="{{media url="Working_principle_of_reciprocating_compressor.jpg"}}" alt="" />_Working process of reciprocating compressor Working principle of reciprocating compressor Relies on periodic changes in the working volume of the cylinder to compress the gas to achieve the purpose of increasing the working pressure. (The reciprocating movement of the piston in the cylinder causes the decompression to suck the gas, and then compress the gas to a certain pressure and send it out.) The working principle of the piston compressor.
-
06/21/2020
The principle of air-conditioning compressor
Abstract: The air-conditioning compressor plays the role of compressing and driving the refrigerant in the air-conditioning refrigerant circuit. Air-conditioning compressors are generally installed in outdoor units. What is the principle of air-conditioning compressor? What is the reason why the air conditioner compressor does not start? How to replace the air conditioner compressor? The compressor is the heart of the refrigeration system of the air conditioner. The refrigerant circulation or flow in the system is achieved by the operation of the compressor. Once the compressor stops, cooling is over. The compressor compresses the refrigerant as<img src="{{media url="magefan_blog/The_principle_of_air-conditioning_compressor.jpg"}}" alt="" />
-
06/15/2020
Reasons for refrigerator compressor not working
Reasons for refrigerator compressor not working Reason one: Is the external power supply and compressor input voltage normal? Check whether the power supply and compressor input voltage meet the standard requirements (187 volts to 242 volts), whether 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦
-
08/17/2020
The function and selection method of throttling capillary in industrial chiller
The capillary tube in the industrial chiller is a pure copper tube with a specified length and a very thin diameter. Its inner diameter is generally between 0.5-2mm. Choose the appropriate length according to the size of the chiller, and then process it i碌7館2 䀀 締眪
-
08/19/2020
Why do industrial chillers need to replace high-quality antifreeze regularly
When the industrial chiller is running, there are high requirements for the use of antifreeze. Ordinary equipment cannot use high concentration antifreeze. If the concentration of antifreeze is high, it takes a long time to warm up before operating the equipment.
-
09/17/2020
Sensor basic knowledge and common terms
1. Sensor: a device or device that can sense the prescribed measurement and convert it into a usable output signal according to a certain rule. Usually composed of sensitive components and conversion components. ① Sensitive element refers to the part of the sensor that can be directly (or responded) to be measured.
-
07/04/2020
Compressor operation in the heart of the refrigeration system in 2020
Compressor operation in the heart of the refrigeration system in 2020 A compressor is a fluid machine that raises low-pressure gas to high-pressure gas. It sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the motor, and discharges high-temperature and high-pressure refrigerant gas to the exhaust pipe to provide power for the refrigeration cycle, thereby achieving compression-condensation (heat release) )-Expansion-evaporation (heat absorption) refrigeration cycle.
-
04/03/2024
24 Famous Industrial Robot Companies Worldwide
In recent years, the robot industry has risen rapidly around the world. At present, five major robot development areas have been formed, in Europe, the United States, Japan, China, and South Korea. The following lists 24 representative robot companies. Let’s take a look.
-
06/23/2022
How to Install a HMI and 4 Common Failures?
In nearly any assembly line, or manufacturing plant, employees work with touchscreens every day.
-
09/05/2020
Development of all low-voltage small air separation equipment
In the 1990s, with the deepening of reforms and technological progress, large-scale air separation and liquefaction equipment provided the ability and means to transport liquid products. Tank trucks for liquid oxygen, liquid nitrogen and liquid argon were sold all over the country.