Hitachi Reduction Drive Gearbox Speed Reducer CA19-010-5 200V
Type: Gearbox
Brand: Hitachi
There is no price at present, you can Request a Quote
Series:CA
Size:19
Power:0.1KW
Ratio:5
Type: Gearbox
Brand: Hitachi
There is no price at present, you can Request a Quote
Type: Gearbox
Brand: Hitachi
There is no price at present, you can Request a Quote
Panasonic Servo Motor MSMA082C1E
JSCC Speed Reducer 70GK120H
MOONS Electric Motor AM17HD6426-05N
Unitta Belt 3M-3174
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTac Solenoid Valve 3V308NOA
Panasonic Air Conditioner LAH18KL1
SMC Safety Valve ZP2V-B01W6-10
06/14/2020
The air compressor is the same as the refrigeration compressor in that it is the same compressor, the difference is that its working principle and working medium are different.
07/18/2020
Safety operating rules for Freon refrigeration compressor units in cold storage Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
08/09/2020
power supply Rosemount temperature transmitter FOUNDAIION fieldbus uses standard fieldbus power supply. The operating voltage of the transmitter is 9 to 32Vdc with a maximum of 11 mA. The rated voltage at the transmitter end is 42.4V dc, Wiring diagram
07/04/2020
okmarts.com platform compressor technology experts tell you why the air conditioner can be cooled In the summer, I believe that many people's feelings must be hot, scorching heat, sweating, etc. At this time, air conditioning is naturally essential equipment. If the air conditioner in your home is not cooling, then the air conditioner becomes a decoration.
07/08/2022
A mechanical seal is simply a method of containing fluid within a vessel (typically pumps, mixers, etc.) where a rotating shaft passes through a stationary housing or occasionally, where the housing rotates around the shaft.
09/04/2021
The throttle Position Sensor (TPS), located on the butterfly spindle, is operated by the throttle, and its installation varies according to the structure.
10/16/2020
Every year in the refrigeration peak season, there are always some non-original Copeland compressors from OEM or refurbished companies appearing on the market. Due to the current many models of Copeland compressors, the market is relatively chaotic, which will affect purchases.
09/04/2020
The oil return check valve is composed of valve body, steel ball, steel ball seat, spring and other elements. The oil and gas mixture compressed by the main engine of the air compressor is initially separated in the oil and gas tank by centrifugal force.
06/21/2020
Operation process of automobile air-conditioning refrigeration system and the role of pressure switch From top to bottom, automobile air conditioners are mainly composed of blowers, evaporators, pressure switches, dryers, expansion valves, condensers, and the most source compressors. The operation process of this air-conditioning system is: heat dissipation,