CONCH HMI HM-782A
Type: HMI
Brand: Conch
Type: HMI
Brand: Conch
Type: HMI
Brand: Conch
CONCH HMI HM-770A
CONCH HMI HM-782S
CONCH HMI HM-670S
CONCH HMI HM-630S
Delta HMI HMC07-N511H52
Weintek HMI MT6070iH1EV
Siemens HMI 6AV2 124-1GC01-0AX0
Weintek HMI MT6100iV2EV
Yaskawa Servo Motor SGMAS-04A2A2C
Delta Servo Drive ASD-A2-0121-L
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Evermore Tool for Metal Cutting E2-40X8
LEEMIN Filter HBX-25-30
Siemens Circuit Breaker 5SL6263-7CC
DHF Tool for Metal Cutting ULE1604X
01/04/2021
Noise control of a two-stage screw refrigeration compressor From a Department of Compressor Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, 710049 Shaanxi, China b Suzhou Academy, Xi’an Jiaotong University, 215123 Jiang 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
07/14/2020
Compressor operation requirements The first load operation of the compressor is carried out after the empty vehicle operation and purging are completed. The compressor should be operated according to the following requirements:
12/13/2023
At present, data centers mainly use two types of refrigerants. One is R410a, which is mainly used in small or medium-sized data centers with air conditioning cooling capacity of 300-400 KW.
04/04/2023
The compressor is the energy core of the air-conditioning refrigeration (heat) system. In the refrigeration system, it mainly plays the role of compressing the refrigerant and promoting the continuous circulation of the refrigeration oil.
02/20/2023
Butterfly valve is a kind of valve that opens, closes, and adjust medium flow by using disc type hoist to turn back and forth about 90 °.
09/30/2022
This article introduces the basic knowledge, working principle, selection and related FAQs of servo motors.
09/12/2022
A circuit breaker refers to a switching device that can close, carry and break current under normal circuit conditions and can do the same under abnormal circuit conditions within a specified time.
06/14/2020
Working principle of refrigeration compressor
11/27/2023
Recently, the HP notebook for personal use prompts that the fan is broken when it is turned on. I decisively placed an order online and bought a replacement fan.