Rockwell A-B HMI 2711P-K15C4D2
Type: HMI
Brand: Rockwell/A-B
Please click Send us the order information , we will contact you as soon as possible !
Type: HMI
Brand: Rockwell/A-B
Type: HMI
Brand: Rockwell/A-B
Mitsubishi HMI GT1662-VNBD
Siemens HMI 6AV6 545-0CC10-0AX0
Delta HMI DOP-B07E411
Cermate HMI PL057-TST1A-F1RN
Yaskawa Servo Motor SGMAS-04ACA61-Y2
Mitsubishi Servo Drive MR-J2S-40A-S004
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Danfoss Compressor MTZ160HW3VE
SAMXON Capacitor 25V 680UF
DELIXI Solenoid Valve 4M220-08
02/07/2022
In some cases, you would find that the compressor motor starts and runs normally, but it cannot compress the refrigerant.
06/29/2022
There are several common modes of failure for variable displacement piston pumps. Understanding these modes of failure, the causes, warning signs, and the prophylactic means of monitoring will help you to reduce unscheduled downtime.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
11/21/2023
The power supply, CPU, chipset, memory, and graphics card in the computer case can generate a lot of heat.
07/10/2022
You might be asking yourself, why are my seals failing so fast, and how can I prevent this from happening? This topic rings true among operators and engineers in plants of all sizes and industries.
12/24/2022
Erbium doped fiber amplifiers are the most widely used optical amplifiers in optical fiber communications.
09/07/2020
With the development of science and technology, air compressors, as an important power equipment, are widely used in many industrial fields such as machinery, metallurgy, building materials, electronics and electricity, chemicals, food, and textiles.
01/03/2023
Solenoid coils are built using the presence of a magnetic field around a wire. It is wound in a spiral shape to strengthen the magnetic field, i.e.
01/16/2024
Industrial fans are fan equipment specially designed for industrial environments, with powerful wind force and stable performance.
06/14/2020
What is an air-cooled heat pump Introduction of knowledge about air-cooled heat pump What is an air-cooled heat pump-Introduction to an air-cooled heat pump