IWAYA DENKI Water Pump 501ST615
- Specifications
- Q&A
- Reviews
Kw:1.5
Voltage(V):200/220
Kg:27.5
MINAMOTO Water Pump GD(2)65-30
PROCON Water Pump 113S100F31GC095
MINAMOTO Water Pump YLGB50-18
WALRUS Water Pump TPK4T8-8
MINAMOTO Water Pump YLGB40-16
TTO Mechanical Seal 30×48×7
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
MAC Solenoid Valve 117B-291BAAA
TTO Oil Seal TC 44*65*11
Hitachi Compressor E405DHD-36D2G
Sanyo Denki Fan 9BMB12P2K01
08/15/2020
In recent years, we have seen a lot of news about cold storage fires. Once a cold storage causes a fire, it will not only cause economic losses to us, but also may cause safety problems.
08/06/2020
Electromagnetic valve (Electromagnetic valve) is an industrial equipment controlled by electromagnetic. It is an automation basic component used to control fluid. It is an actuator and is not limited to hydraulic and pneumatic.
07/26/2023
A heat pump is an essential part of many homes, providing both heating and cooling to keep the indoor environment comfortable. Like any other appliance, it can sometimes develop issues that require attention. One common problem that homeowners may face is a heat pump making loud noise when turning off.
04/11/2022
The expansion valve is installed at the inlet of the evaporator. Its function is to eject the high-temperature and high-pressure liquid refrigerant from the receiver dryer from the small hole of the expansion valve.
09/07/2020
When buying an air compressor, in addition to the purchase cost, how to reduce electricity expenses? How to extend the service life of the air compressor? How to provide air pressure smoothly?
08/07/2020
Industrial chillers are commonly used refrigeration equipment in the industrial refrigeration industry. They are characterized by a wide range of types, complete models, affordable prices, special customization, and a wide range of applications.
09/06/2020
Everyone knows that screw air compressors have high requirements for oil. However, air compressors are easily mixed with others during use, which will not only affect the work of the air compressor, but also easily cause damage to the air compressor.
07/15/2020
Please pay attention to the direction of the terminals in the junction box (single-phase: R, S, C; three-phase: T1, T2, T3). In order to ensure the normal start-up and operation of the Copeland refrigeration compressor, the power supply voltage cannot be lower than 10% of the Copeland compressor rated voltage.
01/11/2021
[Case] Air conditioner compressor does not work after Mitsubishi Pajero overhaul Failure phenomenon: The Mitsubishi Pajero off-road vehicle uses a 6G72 engine. The air-conditioning compressor does not work after the car is overhauled and the condenser 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.