KAWASAKI Piston Pump K3VL112/B-1NRKM-PO
Type: Piston Pump
Brand: KAWASAKI
Type: Piston Pump
Brand: KAWASAKI
Type: Piston Pump
Brand: KAWASAKI
FURNAN Piston Pump VPS-L-16-A1
FURNAN Piston Pump VPS-10-A2-FR
HPC Piston Pump P16-C2-F-R-01
NACHI Piston Pump PVS-0B-8N0--30
SMC Proportional Valve ITV1030-311N4
KOMPASS Check Valve MBP-06-B
JANUS Overflow Valve D5-02-3C-D
Kompass Vane Pump VFA3-15F-A3
Boden Gear Pump BAP2A0D3C0L1
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
EAO Switch EUS-704.01-5373
IFM Sensor PN3160
CHELIC Solenoid Valve SN-8102 DC24V
06/14/2020
Screw refrigeration compressor VS piston refrigeration compressor, don't confuse Distinguish from type Screw refrigeration compressors and piston refrigeration compressors are positive displacement compressors, while screw refrigeration compressors ar 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧܆ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
02/09/2022
As hot summer is coming, air compressor maintenance workers will also usher in the busiest season of the year.
06/14/2020
BRAZIL: Compressor manufacturer Embraco will host two free educational webinars in June, one covering refrigeration fundamentals, the other on the use of flammable “natural” refrigerants in commercial refrigeration.
08/21/2020
Nowadays, whether it is the scorching heat of the summer or the severe winter, the business of the dessert shop is so good that the ice machine naturally works non-stop throughout the year.
07/25/2020
Household air conditioners generally cannot adjust the evaporation temperature! The cold storage and other devices can be adjusted in small amounts, and the increase in the evaporation temperature is mainly in the design and manufacturing stage!
09/02/2020
Centrifuge and screw air compressor are currently the air compressors with a high market share. Today, I will tell you what are the differences between centrifuges and screw air compressors. I hope this article can help you.
04/28/2023
VRV (Variable Refrigerant Volume) air conditioning system was developed and launched by Daikin Industry Co., Ltd. in Japan in 1982. VRV has also become the registered trademark of Daikin variable refrigerant volume multi-split system.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
09/05/2020
Single-screw and twin-screw manufacturing process of twin-screw is more complicated than single-screw in terms of structure, and the difference in service life and working efficiency is not very big,
07/08/2022
A mechanical seal is simply a method of containing fluid within a vessel (typically pumps, mixers, etc.) where a rotating shaft passes through a stationary housing or occasionally, where the housing rotates around the shaft.