KYOWA Transmitter PAV-300KR
There is no price at present, you can Request a Quote
- Specifications
- Q&A
- Reviews
There is no price at present, you can Request a Quote
There is no price at present, you can Request a Quote
Meas Transmitter M5156-10286X-020BG
Danfoss Transmitter 060G593705
Huba Control Transmitter 692.9190071A1
Senex Transmitter DG1300-BZ-A-2-30
METTLER TOLEDO Conductivity Meter F3-Field
Summit Pressure Gauge SUMMIT655
Yokogawa Temperature Controller UM330-02
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Ferraz Shawmut Fuse DN00GB69V50L
NJK Oil Seal 22x28x4
Balluff Sensor BAW0015
SPRAGUE Capacitor 50V 150UF
06/27/2020
The sign of the normal operation of the refrigeration unit 1. There is no knocking sound in the piston refrigeration compressor, the compressor is operating normally, the expansion valve opening is adjusted properly, and there is only compressor suction and exhaust sound during operation, and no knocking or other abnormal sounds are produced.
08/14/2020
With the advent of summer, the maintenance of refrigerated trucks is becoming more and more important. In order to prevent the high temperature in summer from damaging the surface of the refrigerated truck,
11/05/2022
The thermostatic expansion valve (TXV or TEV), also called the thermal expansion valve, controls the openness degree through the control of the superheat of the gaseous refrigerant at the outlet of the evaporator.
08/24/2022
The actuator is an indispensable and important part of automatic control system. Its function is to accept the control signal sent by the controller and change the size of the controlled medium
07/18/2020
Low-temperature chiller refrigeration system operating conditions and adjustments Nowadays, chillers are widely used in the refrigeration industry, and the refrigeration working fluid is usually R22 (also R404a) and so on. In order to facilitate operation and maintenance and reduce the installation location, the refrigeration compressor
03/14/2021
1.Maintenance of operating environment of servo driver In order to prolong the service life of the servo driver, the following problems should be paid attention to in the process of use. Temperature, humidity, dust, vibration, input voltage and other factors should be considered for the system environment.
06/23/2020
If the air conditioner is used for a long time, Freon will be consumed normally, causing the air conditioner to have no previous cooling state; the area of the room itself is relatively large, but it is equipped with a small number of air conditioners; the outdoor unit of the air conditioner is installed outdoors, and it will adsorb on it for a long time. Dust and other reasons will cause the air conditioner to not cool. <img src="{{media url="magefan_blog/What_s_wrong_with_the_air_conditioner_not_cooling3.jpg"}}" alt="" />
06/21/2020
The principle of centrifugal compressor structure Structure principle of centrifugal compressor <img src="{{media url="The_principle_of_centrifugal_compressor_structure.jpg"}}" alt="" /> Centrifugal compressor is composed of rotor, stator and bearing. The impeller and other parts are sleeved on the main shaft to form a rotor. The rotor is supported on the bearing and driven by the power machine to rotate at high speed.
07/05/2020
What sparks can be produced by the combined use of electronic expansion valve and compressor Electronic expansion valve and compressor are indispensable refrigeration accessories in refrigeration equipment and refrigeration equipment, and they are used together with high efficiency.
06/23/2022
In nearly any assembly line, or manufacturing plant, employees work with touchscreens every day.