LEIYA Air Compressor M489-180L
Type: Air Compressor
Brand: LEIYA
pressure(MPa):0.8
Exhaust volume(L/min):1000
Rated voltage:220V 50HZ
Tank capacity(L):180
size(cm):145*40*86
Breathing time:100"
Type: Air Compressor
Brand: LEIYA
Type: Air Compressor
Brand: LEIYA
SMC Proportional Valve ITV3050-33F4L
Panasonic PLC FPO-SL1
Schneider Contactor LC1R0910M5N
PA Safety Valve VS220
AoQiLi Electrical Motor 5IK90GN-AR
Ingersoll Rand Filter 35288380
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Panasonic Servo Drive MSDB045A1A11
Honeywell Sensor SS94A2
Yaskawa Servo Motor SGM7J-02AFA61
05/29/2023
Air conditioning systems have several components that assist in the cooling of the air. These components are the compressor, condenser and evaporator.
06/24/2020
1.If it is because of the weather, you need to change the refrigerator to another location. 2. When used in winter, you can turn on a compensation switch in the refrigerator. 3. It is necessary to check whether the compressor is damaged. 4. If the modulation gear is incorrect, you can adjust the gear higher. 5. If the refrigerant is not enough, the problem of non-refrigeration can be solved after the fluorine content is added.
09/06/2022
The nominal pressure of the overflow valve is determined by the operating pressure, the service temperature range of the safety valve is determined by the operating temperature
08/02/2021
Because of the acceleration of urbanization, commercial air conditioners have developed rapidly in recent years.
06/13/2022
"HMI" stands for Human Machine Interface. These devices are also known as Man Machine Interface (MMI), Operator Interface Terminal (OIT), Local Operator Interface (LOI)
08/15/2020
Due to the high temperature in summer, some products that are more sensitive to temperature are easily affected by temperature. The use of semi-hermetic refrigeration compressors has a temperature limit.
07/15/2020
About the built-in pressure relief valve (IPR valve) of Copeland compressors Among the built-in protection devices of Copeland compressors ZB15-ZB48, ZF06-ZF25, there is a small pressure protection device called built-in pressure relief valve (IPR valve). Below we briefly talk about the work of the built-in pressure relief valve.
06/14/2020
What is a refrigeration compressor and the working principle of a refrigeration compressor A refrigeration compressor is the most important equipment in a refrigeration device, and is usually called the host in the refrigeration device. Refrigerant vapor ﰸ2 䀀 ᅵ皥
08/29/2020
How to achieve zero failure of enterprise compressor equipment
06/14/2020
Detailed process of refrigeration compressor replacement After confirming that there is only a problem with the compressor and it needs to be replaced, proceed to prepare for the replacement of the compressor. Specific steps are as follows: