OMRON Power Supply S8E1-01524D
People who bought this item also viewed
OMRON Power Supply S8VS-48024A
OMRON Power Supply S8FS-C03515
Mean Well Power Supply PSP-500-24
Fanuc Power Supply IC697PWR711
ZIPPY Power Supply HP2-6500P
SIEMENS Servo Motor 1FK7044-4CF71-1QA0
Parker Servo Drive MPA-25-205L
Siemens Transmitter 7MF4033-3GC00-2AB6
Keyence PLC CPU MODULE KV-700
Delta Fan PFB0812EHE
XD Electric Motor XD-3IK15RGN-C
SAMSUNG RAM Card M393A2K40CB2-CTD
Beckhoff Module EL6930
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Haier Air Conditioner KFR-50LW-03JAA23A
Recent related posts
-
07/16/2020
Main features of semi-closed scroll compressor
1. On-site maintenance: The shell of the half-sealed scroll compressor can be disassembled, and the horizontal cast iron body is fixed by bolts. 2. Patented flexible scroll technology: compact structure, extremely low vibration-quiet operation and higher tolerance to liquids and magazines.
-
07/27/2020
The use and maintenance operation of screw unit
Parallel unit: generally composed of the same type of compressor, but also can be composed of different types of compressors. It can be composed of the same type of compressor, or it can be composed of different types of compressors (such as piston machine + screw machine). As shown below:
-
07/22/2020
Safety Operating Regulations for Freon Refrigeration Compressor Unit
Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/17/2023
How to Add Oil to Semi-Hermetic Compressor: A Step-by-Step Guide
If you work in the refrigeration or air conditioning industry, you know how important it is to keep your compressors properly lubricated.
-
03/11/2022
Is It Necessary to Replace Your Refrigerator Compressor?
The compressor is like the heart of humans, which plays a vital role in the refrigerator. A compressor is key to improve the performance of your refrigerator.
-
07/04/2020
Several common failures reported by Taikang compressor customers
No matter what product business you do, customer feedback and market research are very important. If you come up with a product, the customer's response is not good, and no matter how much effort you make, how much publicity will be useless and a waste of time.
-
05/18/2023
What is an AC Compressor? Everything You Need to Know
The air conditioner is one of the most used home appliances in hot summer. We all know that the air conditioner includes two parts: the outdoor unit and the indoor unit.
-
01/15/2021
How to clean the air conditioner
Cleaning the external unit of the air conditioner is conducive to improving the operating efficiency of the air conditioner and extending the service life. How to clean the air conditioner external machine, what problems should be paid attention to when c 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦
-
07/04/2020
Coronavirus’ business impact: Oil Free Compressor Market Size, Share – Global Industry Report, 2018 to 2028
COVID-19 (Coronavirus) has resulted in many advantages and disadvantages for companies in the Oil Free Compressor market. Research report of this Oil Free Compressor market is highlights key strategies that can help reduce the impact of COVID-19 on diverse business practices.