DAIKIN Overflow Valve JRB-G10-3-13
- Specifications
- Q&A
- Reviews
Maximum flow rate L/min:380
Maximum pressure:21MPa
TOYOOKI Overflow Valve HRU3ー80G*K(D)ー06
ASHUN Check Valve TCV-06G
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Daikin Piston Pump V50A2R-20
TWIDEC Relay TH3-25DA/470/eba
RK Industrial Chain golden 520KRO
Baumer Sensor IFRM 04P17A1/KS35PL
Sonnenschein Battery A412/230 F10
06/24/2020
Different cooling methods of refrigerators have different advantages, mainly depending on which cooling method is selected. The direct cooling refrigeration type is cheap, relatively energy-saving, and has good fresh-keeping and moisturizing properties, but the temperature is uneven, and it needs to be defrosted frequently.
06/14/2020
Refrigeration compressor motor burnout detection and maintenance methods, quickly collect it! What are the methods of detection and maintenance of refrigeration compressor motor burnout? Do your friends know? Let's get to know more with the coldest bacte 器2 䀀
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
06/14/2020
Scroll compressor
05/09/2022
Detection method: First, measure its make-break with a multimeter. If the resistance value approaches zero or infinity, it indicates that the coil is short circuited or open circuited.
07/19/2022
An oil-free lubricating pneumatic diaphragm pump belongs to the field of pneumatic machinery.
07/09/2020
Study accurate information about the Medical Air Compressor Market: Statistics, Facts and Figures, Growth Overview, Size, Major Players, Swot Analysis Industry Outlook and Regional Analysis, and Forecast To 2029. Extensive Study on Impact of the novel coronavirus (COVID-19) pandemic on the Medical Air Compressor market originally based on Current Research of Potential Growth Challenges and Future Progress till 2029.
09/11/2020
High exhaust temperature is the most common failure of screw air compressors, and its harm is also greater. Long-term operation of equipment under high exhaust temperature conditions mainly has the following hazards:
08/15/2020
Perhaps many friends are not very familiar with industrial refrigerators. In fact, this kind of equipment is aimed at refrigeration equipment in industrial production and can provide the most
09/06/2020
At present, synthetic lubricants are widely used in the compressor field. Among them, oil-injected and oil-immersed rotary screw air compressors and large reciprocating compressors are one of the most used markets. For example, the sales volume of synthetic compressor oil in Western Europe was 6000t in the late 1980s, and it rose to 10000 in the early 1990s. The sales volume in the United States has exceeded 15,000 tons, and it is increasing at a rate of more than 10% per year.